Optic nerve sheath diameter sonography for the diagnosis of increased intracranial pressure: a systematic review and meta-analysis protocol.

Koziarz Alex, Sne Niv, Kegel Fraser, Alhazzani Waleed, Nath Siddharth, Badhiwala Jetan H, Rice Timothy, Engels Paul, Samir Faidi, Healey Andrew, Kahnamoui Kamyar, Banfield Laura, Sharma Sunjay, Reddy Kesava, Hawryluk Gregory W J, Kirkpatrick Andrew W, Almenawer Saleh A

СтатьяПеревод в очереди

Аннотация

INTRODUCTION

Increased intracranial pressure (ICP) is a significant neurological issue that may lead to permanent neurological sequelae. When evaluating patients with traumatic brain injury, it is crucial to identify those with high ICP in order to expedite ICP lowering measures and maintain adequate cerebral perfusion. Several measures are used to recognise patients with increased ICP including CT scan, MRI, ICP monitor, and lumbar puncture (LP). However, these tests can be invasive, associated with radiation exposure, contraindicated, or not readily available. Ultrasonography measurement of the optic nerve sheath diameter (ONSD) is proposed as a non-invasive and quick measure to identify high ICP. The aim of this systematic review and meta-analysis will be to examine the accuracy of ONSD sonography for increased ICP diagnosis.

METHODS AND ANALYSES: We will include published and unpublished randomised controlled trials, observational studies, and abstracts, with no publication type or language restrictions. Search strategies will be designed to peruse the MEDLINE, Embase, Web of Science, WHO Clinical Trials, ClinicalTrials.gov, CINAHL, and the Cochrane Library databases. We will also implement strategies to search grey literature. Two reviewers will independently complete data abstraction and conduct quality assessment. Included studies will be assessed using the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) tool. We will construct the hierarchical summary receiver operating characteristic curve for included studies and pool sensitivity and specificity using the bivariate model. We also plan to conduct prespecified subgroup analyses to explore heterogeneity. The overall quality of evidence will be rated using Grading of Recommendations, Assessment, Development and Evaluations (GRADE).

ETHICS AND DISSEMINATION: Research ethics board approval is not required for this study as it draws from published data and raises no concerns related to patient privacy. This review will provide a comprehensive assessment of the evidence on ONSD sonography diagnostic accuracy and is directed to a wide audience. Results from the review will be disseminated extensively through conferences and submitted to a peer-reviewed journal for publication.

PROSPERO REGISTRATION NUMBER: CRD42017055485.

CLINICAL TRIAL NUMBER: Trial registration number is NCT00783809.

Для цитирования: Koziarz Alex, Sne Niv, Kegel Fraser, Alhazzani Waleed, Nath Siddharth, Badhiwala Jetan H, Rice Timothy, Engels Paul, Samir Faidi, Healey Andrew, Kahnamoui Kamyar, Banfield Laura, Sharma Sunjay, Reddy Kesava, Hawryluk Gregory W J, Kirkpatrick Andrew W, Almenawer Saleh A. Optic nerve sheath diameter sonography for the diagnosis of increased intracranial pressure: a systematic review and meta-analysis protocol.. BMJ open. 2017. DOI: 10.1136/bmjopen-2017-016194.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.