Endoscopic Decompression with a Transanal Drainage Tube for the Treatment of Hirschsprung's Disease in Newborns.
Аннотация
Background
To evaluate the effectiveness and safety of endoscopic decompression with a transanal drainage tube (ED-TDT) in the treatment of neonatal Hirschsprung's disease (HD). Materials and
Methods
Six newborns (4 boys and 2 girls; age at operation 9-29 days, median 24 days) were admitted to our hospital due to the delayed passage of meconium after birth, abdominal distension, and vomiting. HD was diagnosed by the retrograde enema radiography. All patients underwent ED-TDT for decompression of the dilated colon. During the operation, an endoscope was inserted through the anus to the ascending colon or ileocecal region, which was then used to insert a guidewire to the ascending colon. The endoscope was then removed, and a colorectal drainage tube was introduced over the guidewire. This drainage was placed until a pull-through procedure was performed.
Results
The ED-TDT was successfully performed in all newborns. The intraoperative rectal biopsy confirmed the diagnosis of HD. The duration of the operation was 25-70 minutes (median 52.5 minutes). There were no perforations, bleeding, or other complications after surgery. After surgery, the abdominal distention was significantly relieved, and the babies could be fed with milk after 6 hours. These babies were discharged after 2-11 days (median 2.5 days) and underwent a pull-through procedure after 1-3 months (median 3 months).
Conclusions
ED-TDT is a safe and effective treatment for neonatal HD before a pull-through procedure. It could be used as an alternative therapy to colostomy.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.