MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.healun.2013.08.014

Медицинская библиотека · The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation · 2013

HLA and MICA allosensitization patterns among patients supported by ventricular assist devices.

Askar Medhat, Hsich Eileen, Reville Patrick, Nowacki Amy S, Baldwin William, Bakdash Suzanne, Daghstani Jenna, Zhang Aiwen, Klingman Lynne, Smedira Nicholas, Moazami Nader, Taylor David O, Starling Randall C, Gonzalez-Stawinski Gonzalo

Сравнительное исследованиеСтатьяПеревод в очереди

Аннотация

BACKGROUND

Ventricular assist devices (VADs) are increasingly being used as a bridge to transplantation and have been implicated as a risk factor for allosensitization to human leukocyte antigens (HLA). We investigate the association between VAD and allosensitization to human leukocyte antigens (HLA) and major-histocompatibility-complex (MHC) class I-related Chain A (MICA) antigens.

METHODS

We considered all patients who received a VAD at our institution between 2000 and 2009; 89 of them had pre-VAD and post-VAD (≤6 months after implant) HLA antibody screening. A control group of non-VAD heart transplant candidates was constructed with at least 2 pre-transplant panel-reactive antibody (PRA) tests within 8 months. Two controls were randomly selected/VAD patient matched for year (n = 178). Patients and controls with available sera from these time-points were tested by Luminex/flow PRA single-antigen beads and by MICA antibody Luminex single-antigen beads. Medical records were reviewed for comparison of pre-transplant immunologic risk factors and post-transplant outcomes between the 2 groups.

RESULTS

Compared with controls, VAD patients had greater Class I differences between peak and initial PRA (18% vs. 0%, p < 0.0001) and higher peak PRA (24% vs. 6%, p < 0.0001). The differences between the 2 groups in Class II were less pronounced than in Class I. Of patients who had single-antigen testing, VAD implantation was significantly associated with development of new HLA antibody specificities (Class I and/or Class II) post-VAD with an increase in calculated PRA (cPRA) post-VAD compared with controls (16% vs. 0%, p < 0.0001). This risk was still present after adjusting for age, gender, pre-VAD PRA, transfusion and duration of follow-up in a multivariate analysis (p < 0.0001 and 0.02, respectively). There were no differences in development of MICA antibodies between the 2 groups (14% in both). There was no significant difference in the incidence of pre-transplant positive T-cell crossmatch, pre-transplant donor-specific HLA antibodies, rejection episodes or graft survival between the 2 groups.

CONCLUSION

Our results suggest that VAD is associated with significant HLA allosensitization independent of common risk factors.

Для цитирования: Askar Medhat, Hsich Eileen, Reville Patrick, Nowacki Amy S, Baldwin William, Bakdash Suzanne, Daghstani Jenna, Zhang Aiwen, Klingman Lynne, Smedira Nicholas, Moazami Nader, Taylor David O, Starling Randall C, Gonzalez-Stawinski Gonzalo. HLA and MICA allosensitization patterns among patients supported by ventricular assist devices.. The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation. 2013. DOI: 10.1016/j.healun.2013.08.014.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.