BACKGROUND

Electrocardiographic artifacts can present as pseudo-arrhythmia, such as ventricular tachycardia (VT), leading to unnecessary interventions.

CASE SUMMARY: A 47-year-old woman with hypertension, asthma, obstructive sleep apnea, lupus/Sjögren disease, and schizoaffective disorder was admitted for failure to thrive. Telemetry suggested polymorphic and monomorphic VT, prompting a rapid response. She was asymptomatic and hemodynamically stable, with a pulse 93/min. A baseline tremor was noted. Post-rapid-response electrocardiogram revealed an normal sinus rhythm with a QTc interval of 460 milliseconds. Preserved QRS complexes were seen to be embedded within the observed VT on telemetry review. Identification of the artifact pattern prevented further unwarranted interventions.

DISCUSSION: Tremor-induced artifacts can present as compelling VT mimics. Stable hemodynamics, concealed QRS complexes, and bedside examination are crucial in distinguishing pseudo-arrhythmia from true arrhythmia.

TAKE-HOME MESSAGES: Electrocardiographic artifacts should be considered in clinically stable patients with telemetry VT alarms. Careful holistic approach to such alarms can avoid unnecessary invasive procedures and antiarrhythmic use.

Для цитирования: Haiy Ata Ul, Basit Muhammad Abdul, Mirza Hasan Mahmood, Wasim Aaima, Jalil Ahmad, Bajwa Ata. Tremor Artifact Presenting as Pseudo-Ventricular Tachycardia.. JACC. Case reports. 2026. DOI: 10.1016/j.jaccas.2026.108029.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.