MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/0363546511408873

Медицинская библиотека · The American journal of sports medicine · 2011

Arthroscopic-assisted reduction and percutaneous cannulated screw fixation for Ideberg type III glenoid fractures: a minimum 2-year follow-up of 18 cases.

Yang Hai-bo, Wang Dong, He Xi-jing

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Traditionally, open reduction and internal fixation is an acceptable choice for treating displaced glenoid articular fracture. Considering some major complications associated with open surgery, however, surgeons have explored a less invasive way to achieve fixation.

PURPOSE: This investigation was undertaken to evaluate the clinical results of arthroscopic-assisted reduction and percutaneous cannulated screw fixation for the treatment of Ideberg type III glenoid fractures.

STUDY

DESIGN

Case series; Level of evidence, 4.

METHODS

Twenty-three consecutive patients with Ideberg type III glenoid fractures underwent arthroscopic-assisted reduction and percutaneous cannulated screw fixation. Eighteen patients (78.3%) were available for the final follow-up, at a mean of 37.6 months (range, 24-61 months). There were 12 men and 6 women, with an average age of 41.2 years (range, 22-62 years). Dominant sides were involved in 10 patients. The mean time from injury to surgery was 5.9 ± 2.7 days.

RESULTS

The average ranges of motion of the affected shoulders at the final follow-up were 162.8° ± 8.3° in forward elevation, 67.2° ± 4.6° in external rotation at the side, and T8 ± 2 in internal rotation. The average visual analog scale pain score was 0.7 ± 0.9 (range, 0-3), the average American Shoulder and Elbow Surgeons score was 96.0 ± 5.4 (range, 80-100), the average Constant-Murley score was 96.8 ± 2.9 (range, 90-100), and the average University of California, Los Angeles, score was 34.3 ± 0.9 (range, 33-35). No hardware failure or redisplacement of the fracture occurred, and all fractures healed without any major complication associated with the surgery.

CONCLUSION

Arthroscopic-assisted reduction and percutaneous cannulated screw fixation is a safe and effective method for the treatment of Ideberg type III glenoid fractures.

Для цитирования: Yang Hai-bo, Wang Dong, He Xi-jing. Arthroscopic-assisted reduction and percutaneous cannulated screw fixation for Ideberg type III glenoid fractures: a minimum 2-year follow-up of 18 cases.. The American journal of sports medicine. 2011. DOI: 10.1177/0363546511408873.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.