MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ajo.2022.02.014

Медицинская библиотека · American journal of ophthalmology · 2022

Optic Disk Pit Maculopathy Treatment Using a Human Amniotic Membrane Patch: One-Year Results.

Caporossi Tomaso, D'Amico Guglielmo, Tartaro Ruggero, Governatori Lorenzo, Scampoli Alessandra, Amorelli Giulia, De Vico Umberto, Rizzo Stanislao

СтатьяПеревод в очереди

Аннотация

PURPOSE: To report the 1-year results of human amniotic membrane patch implantation for optic disc pit maculopathy.

DESIGN

A prospective, consecutive, interventional study.

METHODS

Eleven eyes of 11 patients affected by optic disc pit maculopathy associated with subretinal/intraretinal fluid were included in this single-institution study. A 25-gauge pars plana vitrectomy was performed in all cases, with an implant of a human amniotic membrane patch into the optic disc pit and air was injected as endotamponade. The primary study outcome was the subretinal and intraretinal fluid reabsorption. Secondary outcomes were visual acuity improvement and postoperative complications.

RESULTS

Mean central retinal thickness gradually diminished from 512 ± 137 µm to 243 ± 19 µm, at the 12-month follow-up. The mean visual acuity improved from 20/80 at baseline to 20/32 at the 12-month follow-up. Complete fluid resorption occurred in 9 of 11 (81.8%) eyes and there was partial resorption in 2 eyes (18%). No subretinal fluid recurrence was observed during the 12-month follow-up. No intraoperative or postoperative complications were reported during the follow-ups. The amniotic membrane patch remained detectable inside the pit for the entire follow-up time.

CONCLUSION

An amniotic membrane plug may be effective for improving optic disc pit maculopathy. All cases had an anatomical improvement and encouraging visual acuity recovery.

Для цитирования: Caporossi Tomaso, D'Amico Guglielmo, Tartaro Ruggero, Governatori Lorenzo, Scampoli Alessandra, Amorelli Giulia, De Vico Umberto, Rizzo Stanislao. Optic Disk Pit Maculopathy Treatment Using a Human Amniotic Membrane Patch: One-Year Results.. American journal of ophthalmology. 2022. DOI: 10.1016/j.ajo.2022.02.014.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.