MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/pan.14024

Медицинская библиотека · Paediatric anaesthesia · 2020

Implementation of a spinal anesthesia and sedation protocol that reliably prolongs infant spinal anesthesia: Case series of 102 infants who received spinal anesthesia for urologic surgery.

Handlogten Kathryn, Warner Lindsay, Granberg Candace, Gargollo Patricio, Thalji Leanne, Haile Dawit

СтатьяПеревод в очереди

Аннотация

BACKGROUND

The use of spinal anesthesia in infants is seeing resurgence as an alternative to general anesthesia.

AIMS: Our primary aims are to describe our institution's experience introducing a spinal anesthesia and sedation protocol for infants undergoing urologic surgery, to describe methods of improving prolonged anesthesia, and to describe the failure rate of spinal anesthesia in these patients. Sedation was provided for some infants with intranasal dexmedetomidine ± fentanyl.

METHODS

This is a retrospective case series examining infants aged 1-<14 months who received spinal anesthesia for circumcision, orchiopexy, orchiectomy, hypospadias repair, or epispadias repair. The electronic medical record was reviewed and compared with unmatched historical controls who received general anesthesia.

RESULTS

A total of 230 patients underwent a urologic procedure; 102 patients received spinal anesthesia and 128 received general anesthesia. Length of surgical time with spinal anesthesia ranged from 4 to 189 minutes. The hospital length of stay was shorter in the spinal anesthesia group (median [IQR] of 5.3 hours [4.3, 7.2]) compared to the general anesthesia group (17.1 hours [15.6, 17.5]).The median bupivacaine dose was 0.75 mg/kg [0.67, 0.85]. There was one case in which cerebral spinal fluid was unable to be obtained, and one case that required conversion to general anesthesia after surgery had started. There were no cases of apnea, bleeding, infection, or neurologic compromise.

CONCLUSIONS

We describe the successful implementation of an infant spinal anesthesia and sedation protocol and a technique that uniquely provides prolonged surgical anesthesia with a low failure rate. We also report shorter anesthesia time, surgical time, and recovery room length of stay in patients who received spinal anesthesia compared to general anesthesia.

Для цитирования: Handlogten Kathryn, Warner Lindsay, Granberg Candace, Gargollo Patricio, Thalji Leanne, Haile Dawit. Implementation of a spinal anesthesia and sedation protocol that reliably prolongs infant spinal anesthesia: Case series of 102 infants who received spinal anesthesia for urologic surgery.. Paediatric anaesthesia. 2020. DOI: 10.1111/pan.14024.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.