MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3791/51632

Медицинская библиотека · Journal of visualized experiments : JoVE · 2014

Implantation of inferior vena cava interposition graft in mouse model.

Lee Yong-Ung, Yi Tai, Tara Shuhei, Lee Avione Y, Hibino Narutoshi, Shinoka Toshiharu, Breuer Christopher K

СтатьяПоддержка NIH: внешняя программаVideo-Audio MediaПеревод в очереди

Аннотация

Biodegradable scaffolds seeded with bone marrow mononuclear cells (BMCs) are often used for reconstructive surgery to treat congenital cardiac anomalies. The long-term clinical results showed excellent patency rates, however, with significant incidence of stenosis. To investigate the cellular and molecular mechanisms of vascular neotissue formation and prevent stenosis development in tissue engineered vascular grafts (TEVGs), we developed a mouse model of the graft with approximately 1 mm internal diameter. First, the TEVGs were assembled from biodegradable tubular scaffolds fabricated from a polyglycolic acid nonwoven felt mesh coated with ε-caprolactone and L-lactide copolymer. The scaffolds were then placed in a lyophilizer, vacuumed for 24 hr, and stored in a desiccator until cell seeding. Second, bone marrow was collected from donor mice and mononuclear cells were isolated by density gradient centrifugation. Third, approximately one million cells were seeded on a scaffold and incubated O/N. Finally, the seeded scaffolds were then implanted as infrarenal vena cava interposition grafts in C57BL/6 mice. The implanted grafts demonstrated excellent patency (>90%) without evidence of thromboembolic complications or aneurysmal formation. This murine model will aid us in understanding and quantifying the cellular and molecular mechanisms of neotissue formation in the TEVG.

Для цитирования: Lee Yong-Ung, Yi Tai, Tara Shuhei, Lee Avione Y, Hibino Narutoshi, Shinoka Toshiharu, Breuer Christopher K. Implantation of inferior vena cava interposition graft in mouse model.. Journal of visualized experiments : JoVE. 2014. DOI: 10.3791/51632.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.