MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.bios.2026.118990

Медицинская библиотека · Biosensors & bioelectronics · 2026

Multiplexed plasmon-enhanced lateral flow assay for early diagnosis of acute kidney injury.

Guo Heng, Liu Yuxiong, Jada Ravi, Liu Ying, Ng Carissa, Payte Aquiles, Xu Jiaying, Malone Connor, Zhao Jie, Pasupuleti Kedhareswara Sairam, Arikan Arda Aidan, Thadani Sameer, Singamaneni Srikanth, Arikan Ayse Akcan, Tian Limei

СтатьяПеревод в очереди

Аннотация

Early diagnosis of acute kidney injury (AKI) remains a major clinical challenge due to the delayed and insensitive nature of conventional markers such as serum creatinine. Urinary protein biomarkers, including neutrophil gelatinase-associated lipocalin (NGAL) and cystatin C (CysC), provide earlier and complementary information on kidney injury, but their clinical translation is limited by the lack of rapid, quantitative, and multiplexed point-of-care (POC) diagnostic tests. Here, we report a multiplexed plasmonic-fluor-based lateral flow assay (p-LFA) that enables sensitive, quantitative, and simultaneous detection of NGAL and CysC. By harnessing ultrabright plasmonic-fluor nanolabels and ratiometric fluorescence analysis, the p-LFA achieves picogram-per-milliliter analytical sensitivity comparable to that of the enzyme-linked immunosorbent assay (ELISA). In addition, the simplified assay format enables sample-to-answer times as short as 10 min, while maintaining sensitivity sufficient for accurate AKI detection. Clinical validation using pediatric urine samples demonstrates a strong correlation with ELISA measurements for both biomarkers. Combined analysis of NGAL and CysC significantly improves AKI diagnostic performance, yielding an area under the receiver operating characteristic curve of 0.973 with a clinical sensitivity of 90.9% and specificity of 91.2% in the studied cohort. Furthermore, a low-cost, portable fluorescence reader enables quantitative performance equivalent to benchtop imaging while dramatically reducing instrument cost and complexity. Collectively, this work establishes a scalable and adaptable p-LFA platform that bridges laboratory-grade immunoassays and practical POC diagnostics, offering a promising solution for early AKI detection and multiplexed biomarker analysis in decentralized healthcare settings.

Для цитирования: Guo Heng, Liu Yuxiong, Jada Ravi, Liu Ying, Ng Carissa, Payte Aquiles, Xu Jiaying, Malone Connor, Zhao Jie, Pasupuleti Kedhareswara Sairam, Arikan Arda Aidan, Thadani Sameer, Singamaneni Srikanth, Arikan Ayse Akcan, Tian Limei. Multiplexed plasmon-enhanced lateral flow assay for early diagnosis of acute kidney injury.. Biosensors & bioelectronics. 2026. DOI: 10.1016/j.bios.2026.118990.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.