MedElevator Войти в исследования
← Поиск публикаций

DOI 10.4103/aam.aam_377_25

Медицинская библиотека · Annals of African medicine · 2026

A Comparative Analysis of the Efficacy of CD117 and Special Stains as Indicators of Mechanical Asphyxial Deaths.

Shekhawat Raghvendra Singh, Panwar Rahul, Rao Meenakshi, Meshram Vikas Premlal, Kumar Meena Suresh, Gnanasekaran Sridevi, Rathore Mohini, Kanchan Tanuj

СтатьяСравнительное исследованиеПеревод в очереди

Аннотация

BACKGROUND

Determining the cause of death in suspected asphyxia is often difficult when external findings are absent. Mast cells (MCs) may provide objective histological evidence of hypoxia.

OBJECTIVE

To compare the efficacy of immunohistochemistry (IHC) using CD117 with Toluidine Blue (TB) and Giemsa (GM) stains in detecting mast cells in asphyxial and non-asphyxial lung tissues.

MATERIALS AND

METHODS

Lung samples from 164 medicolegal autopsies at AIIMS Jodhpur were studied, 57 asphyxial and 107 non-asphyxial deaths. Peribronchial and perialveolar regions were examined using TB, GM, and IHC (CD117). Mean mast cell counts were compared using Mann-Whitney U and Kruskal-Wallis tests.

RESULTS

Mast cell counts were significantly higher in asphyxial cases. Peribronchial counts: IHC 2.27 ± 1.02, TB 2.29 ± 1.19, GM 0.84 ± 0.59. Perialveolar counts: IHC 0.74 ± 0.12, TB 0.10 ± 0.19, GM 0.01 ± 0.51. IHC was more sensitive than GM (P < 0.001), while TB showed comparable efficacy to IHC.

CONCLUSION

CD117-based IHC is the most sensitive method for identifying mast cells in asphyxial lungs, though TB remains a valuable low-cost option. Mast cell analysis can serve as an adjunct marker in diagnosing mechanical asphyxia.

Для цитирования: Shekhawat Raghvendra Singh, Panwar Rahul, Rao Meenakshi, Meshram Vikas Premlal, Kumar Meena Suresh, Gnanasekaran Sridevi, Rathore Mohini, Kanchan Tanuj. A Comparative Analysis of the Efficacy of CD117 and Special Stains as Indicators of Mechanical Asphyxial Deaths.. Annals of African medicine. 2026. DOI: 10.4103/aam.aam_377_25.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.