MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ejrad.2025.112651

Медицинская библиотека · European journal of radiology · 2026

Artificial intelligence performance in image-based biliary atresia identification: a systematic review and meta-analysis.

Halimi Anis, Msherghi Ahmed, Nounou Mohamedhen Vall, Elhabbasi Basma Mansor, Abdulrahman Bushray, Abouelella Ahmed, Shanab Asmaa, Zakraoui Rihane, Farrag Ayatallah Ahmed, Elhadi Muhammed

СтатьяМетаанализСистематический обзорПеревод в очереди

Аннотация

BACKGROUND

Biliary atresia (BA) is a rare condition that can lead to serious health complications. Artificial Intelligence (AI)- based medical imaging has shown potential to improve the detection of BA diagnosis, offering increased accuracy over traditional imaging methods. This meta-analysis aimed to evaluate the diagnostic accuracy of imaging-based AI for detecting BA.

METHODS

The study followed PRISMA DTA guidelines and was registered in the PROSPERO database. The search was performed in PubMed, Web of Science, Embase, and Scopus databases for studies reporting the diagnostic accuracy of imaging-based AI models in detecting BA. Meanwhile, pre-defined eligibility criteria were used for the selection of studies. Pooled sensitivity, specificity, and area under the curve (AUC) were calculated utilizing R 4.4.2. Quality assessment was performed using the Quality Assessment of Diagnostic Accuracy Studies-AI (QUADAS-AI) criteria and the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) tool, and the GRADE approach was applied to evaluate the certainty of the synthesised evidence.

RESULTS

A total of nine studies were included in this meta-analysis. The overall quality of the included studies was moderate to high, although a high risk of bias was noted in the index test domain of several studies. A total of 11,006 patients were analyzed, comprising 2,357 BA cases and 8,649 non-BA cases, with 11,500 ultrasound images. Patient-level analysis revealed pooled sensitivities, specificities, and AUCs of 93.8 % (95 % CI: 86-97.4 %), 93.2 % (95 % CI: 91.8-94.4 %), and 0.94, respectively. Additionally, the pooled results of image-based analysis revealed sensitivity, specificity, and AUC of 86.9 % (95 % CI: 73.7-94.1 %), 94.3 % (95% CI: 90.9-96.4 %), and 0.965, respectively.

CONCLUSION

AI shows satisfactory performance in the imaging-based diagnosis of biliary atresia. It should be regarded as an assistive tool that supports clinical decision-making, and further high-quality studies are needed to confirm its generalizability.

Для цитирования: Halimi Anis, Msherghi Ahmed, Nounou Mohamedhen Vall, Elhabbasi Basma Mansor, Abdulrahman Bushray, Abouelella Ahmed, Shanab Asmaa, Zakraoui Rihane, Farrag Ayatallah Ahmed, Elhadi Muhammed. Artificial intelligence performance in image-based biliary atresia identification: a systematic review and meta-analysis.. European journal of radiology. 2026. DOI: 10.1016/j.ejrad.2025.112651.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.