STUDY

OBJECTIVE

To compare the effectiveness and safety of 2 anterior transobturator mesh methods for treating anterior vaginal wall prolapse.

DESIGN

Randomized controlled study (Canadian Task Force classification I).

SETTING

University hospital.

PATIENTS: Eighty-seven women with anterior vaginal wall prolapse stage ≥2 (Pelvic Organ Prolapse Quantification [POP-Q]) underwent an anterior transobturator mesh procedure using macropore polypropylene mesh.

INTERVENTIONS: Forty-five patients underwent the operation via the conventional 4-point, full-sized mesh method, and 42 patients underwent the operation via a novel 2-point, half-sized mesh method.

MEASUREMENTS AND MAIN

RESULTS

Patient characteristics were comparable between the 2 groups. The anatomic cure rate was significantly lower in the 2-point group compared with the 4-point group at 12 months after surgery (87.2% vs 100%; p = .03). Healing abnormalities were significantly higher in the 2-point group than in the 4-point group (12.8% vs 0%; p = .03). Bladder perforation (2.6% vs 0%), stress urinary incontinence (23.1% vs 22.5%), urinary frequency (12.8% vs 22.5%), and voiding difficulty and dyspareunia (0% vs 0%) were not statistically different between the 2 groups. At linear regression analysis, mean (SD) operation time did not differ between the 2 groups (74.9 [32.7] minutes vs 87.8 [36.7] minutes; p = .11).

CONCLUSION

Compared with the 4-point method, the 2-point anterior transobturator mesh method resulted in a lower rate of anatomic cure and a higher rate of healing abnormality.

Для цитирования: Yuk Jin-Sung, Jin Chan Hee, Yi Kyong Wook, Kim Tak, Hur Jun-Young, Shin Jung-Ho. Anterior transobturator polypropylene mesh in the correction of cystocele: 2-point method vs 4-point method.. Journal of minimally invasive gynecology. 2012. DOI: 10.1016/j.jmig.2012.08.769.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.