MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3928/1081597x-20131217-03

Медицинская библиотека · Journal of refractive surgery (Thorofare, N.J. : 1995) · 2014

Femtosecond laser versus manual clear corneal incision in cataract surgery.

Mastropasqua Leonardo, Toto Lisa, Mastropasqua Alessandra, Vecchiarino Luca, Mastropasqua Rodolfo, Pedrotti Emilio, Di Nicola Marta

Сравнительное исследованиеСтатьяРандомизированное исследованиеПеревод в очереди

Аннотация

PURPOSE: To compare functional and morphological outcomes of femtosecond laser clear corneal incision (CCI) versus manual CCI during cataract surgery.

METHODS

Sixty eyes of 60 patients who underwent CCI during cataract surgery were randomized into two groups: femtosecond laser CCI (30 eyes) and manual CCI (30 eyes).

RESULTS

There were no significant between-group differences in uncorrected distance visual acuity, corrected distance visual acuity, surgically induced astigmatism, and corneal aberrations. Keratometric astigmatism was significantly lower in the femtosecond laser CCI group compared to the manual CCI group at 30 and 180 days (P < .05). Central endothelial cell count was significantly higher in the femtosecond laser CCI group compared to the manual CCI group at 7 and 30 days postoperatively (P < .05). A lower increase of corneal thickness at the incision site was observed at 30 and 180 days postoperatively in the femtosecond laser CCI group compared to the manual CCI group (P < .05). In addition, femtosecond laser CCI showed a better morphology (lower percentage of endothelial and epithelial gaping and endothelial misalignment) compared to manual CCI at different time points. Total phacoemulsification time was significantly lower in the femtosecond laser CCI group (P < .05).

CONCLUSIONS

The femtosecond laser procedure was safe, efficient, and less damaging, as evidenced by lower central endothelial cell loss, lower increase of corneal thickness at the incision site, and better tunnel morphology compared to the manual technique.

Для цитирования: Mastropasqua Leonardo, Toto Lisa, Mastropasqua Alessandra, Vecchiarino Luca, Mastropasqua Rodolfo, Pedrotti Emilio, Di Nicola Marta. Femtosecond laser versus manual clear corneal incision in cataract surgery.. Journal of refractive surgery (Thorofare, N.J. : 1995). 2014. DOI: 10.3928/1081597x-20131217-03.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.