OBJECTIVE

The present study was aimed at determining device-associated infection rates, device use rates and the microbiologic profile of nosocomial infections in a tertiary neonatal intensive care unit (ICU) in Bogotá, Colombia.

METHODS

Prospective nosocomial infection surveillance was implemented in a neonatal intensive care unit for 11 months in line with the High Risk Nursery component of the Colombian Nosocomial Infection Surveillance programme. Patient-days, length of stay, device use rates and device-associated nosocomial infection rates were calculated.

RESULTS

1 998 device days were observed among 2 890 patient days during the 11 months' surveillance. Central venous catheter-related bloodstream infection was the most common device-associated infection for all birth-weight categories. 69,2 % and 100 % of all coagulase negative staphylococci and Staphylococcus aureus infections were methicillin resistant strains and all gram negative rods were susceptible to third generation cephalosporins, carbapenems, ciprofloxacin and piperacillin-tazobactam. Device-associated infection and device use rates in the ICU were higher than Colombian Nosocomial Infection Surveillance reports for October 2004 and reports from Colombia and other Latin-American countries.

CONCLUSIONS

This surveillance identified blood-stream infection as being the most common infection in the ICU in question. Efforts should thus be directed at establishing suitable infection-control practices.

Для цитирования: Contreras-Cuellar Germán A, Leal-Castro Aura L, Prieto Reinaldo, Carvajal-Hermida Alba L. Device-associated infections in a Colombian neonatal intensive care unit.. Revista de salud publica (Bogota, Colombia). 2007. DOI: 10.1590/s0124-00642007000300012.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.