Does ECG monitoring affect resuscitation for neonates with pulseless electrical activity in the delivery room? A simulated, pilot, crossover randomised trial.

Assaad Michael-Andrew, Gariepy-Assal Laurence, Moussa Ahmed

СтатьяРандомизированное исследованиеПеревод в очереди

Аннотация

OBJECTIVE

To evaluate whether ECG monitoring impacts resuscitative steps during simulated neonatal resuscitation in the setting of pulseless electrical activity (PEA) in the delivery room.

DESIGN

This pilot, crossover randomised controlled trial recruited providers in teams of three who participated in two simulation scenarios (PEA with and without ECG monitoring). Teams were randomised to one scenario and then crossed over. All sessions were video-recorded. The primary outcome was time to pulse check once the manikin was programmed to become pulseless. The secondary outcomes were total pulse checks, time to positive pressure ventilation, intubation, chest compressions and administration of epinephrine, and teams' quotes and behaviours during resuscitation. The primary outcome was analysed using Kaplan-Meier survival curve. The secondary outcomes were compared with Wilcoxon signed-rank test. The quotes were analysed using content analysis with pattern coding.

RESULTS

Eighty-two healthcare providers were approached and 30 consented (10 teams). The mean time to check the pulse once the manikin was pulseless was 38.5 s (SD 30.1) without ECG vs 88.1 s (SD 46.1) with ECG (p<0.01). There was a significantly decreased number of pulse checks with the ECG compared with without (p<0.01). Time to intubation, chest compressions, start of positive pressure ventilation and epinephrine administration was not different between the groups. Quotes/behaviours revealed false reassurance and over-reliance on ECG monitoring, repeated pulse check errors and troubleshooting behaviours.

CONCLUSIONS

ECG monitoring in simulated neonatal resuscitation results in delayed recognition of a pulseless state, decreased number of pulse checks and a possible false sense of security. Simulated resuscitation clinical endpoints are unaffected.

Для цитирования: Assaad Michael-Andrew, Gariepy-Assal Laurence, Moussa Ahmed. Does ECG monitoring affect resuscitation for neonates with pulseless electrical activity in the delivery room? A simulated, pilot, crossover randomised trial.. Archives of disease in childhood. Fetal and neonatal edition. 2024. DOI: 10.1136/archdischild-2023-326099.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.