MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00405-024-08603-2

Медицинская библиотека · European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery · 2024

Diagnostic accuracy of intrathecal fluorescein versus other radiological modalities in evaluating non-congenital skull base defects: a systematic review and meta-analysis.

AlSharhan Salma S, Aljubran Hussain J, Alrusayyis Danah F, AlGhuneem Aishah A, AlMarzouq Wasan F, Al Bar Mohammed H, AlSaied Abdulmalik S, Ashoor Mona M, ALEnazi Abdulaziz S, Alghamdi Amal A

СтатьяМетаанализСистематический обзорПеревод в очереди

Аннотация

PURPOSE: The intraoperative detection of cerebrospinal fluid (CSF) leaks during endoscopic skull base surgery is critical to ensure watertight sealed defects. Intrathecal fluorescein (ITF) is a valuable adjunct to intraoperative investigation. Hence, our aim is to summarize the evidence of the efficacy of ITF as an accurate diagnostic modality and reconstruction guide for non-congenital skull base defects.

METHODS

Using the Cochrane Central, MEDLINE, and Embase databases, we identified studies involving the use of ITF in non-congenital CSF leaks which were published until November 2023. The STATA 18 software was used for meta-analysis.

RESULTS

Fourteen studies met the inclusion criteria, in which seven studies were included in the meta-analysis. ITF was used in 1898 (90.3%) of patients, with a detection rate of 88.1%. The overall detection rate of non-congenital CSF leaks among ITF concentrations of 5% and 10% had a statistically significant pooled effect size of 2.6 (95% CI = 2.25, 2.95), while when comparing the ITF to other alternative radiological tests, it was not statistically significant with a mean difference of 0.88 (95% CI = - 0.4, 2.16). Moreover, the pooled prevalence was statistically significant in regards of the complications associated with ITF with an effect size of 0.6 (95% CI = 0.39, 0.82), indicating that 60% of patients who underwent ITF would experience at least one of the measured complications.

CONCLUSION

ITF is considered as an efficient tool in localizing skull base defects. However, there was no significant results when comparing the ITF to other alternative radiological tests. Accordingly, if the ITF intervention is indicated, patients should be carefully selected based on their clinical need.

Для цитирования: AlSharhan Salma S, Aljubran Hussain J, Alrusayyis Danah F, AlGhuneem Aishah A, AlMarzouq Wasan F, Al Bar Mohammed H, AlSaied Abdulmalik S, Ashoor Mona M, ALEnazi Abdulaziz S, Alghamdi Amal A. Diagnostic accuracy of intrathecal fluorescein versus other radiological modalities in evaluating non-congenital skull base defects: a systematic review and meta-analysis.. European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery. 2024. DOI: 10.1007/s00405-024-08603-2.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.