Gastrointestinal endoscopy · 2015

Endoscopic intestinal bypass creation by using self-assembling magnets in a porcine model.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Ryou Marvin, Agoston A Tony, Thompson Christopher C

Аннотация

BACKGROUND AND AIMS: A purely endoluminal method of GI bypass would be desirable for the treatment of obstruction, obesity, or metabolic syndrome. We have developed a technology based on miniature self-assembling magnets that create large-caliber anastomoses (Incisionless Anastomosis System [IAS]). The aim of this study was to evaluate procedural characteristics of IAS deployment and long-term anastomotic integrity and patency.

METHODS: We performed a 3-month survival study of Yorkshire pigs (5 interventions, 3 controls). Intervention pigs underwent simultaneous enteroscopy/colonoscopy performed with the animals under intravenous sedation. The IAS magnets were deployed and coupled with reciprocal magnets under fluoroscopy. Every 3 to 6 days pigs underwent endoscopy until jejunocolonic anastomosis (dual-path bypass) creation and magnet expulsion. Necropsies and histological evaluation were performed. The primary endpoints were technical success; secondary endpoints of anastomosis integrity, patency, and histological characteristics were weight trends.

RESULTS: Under intravenous sedation, endoscopic bypass creation by using IAS magnets was successfully performed in 5 of 5 pigs (100%). Given porcine anatomy, the easiest dual-path bypass to create was between the proximal jejunum and colon. The mean procedure time was 14.7 minutes. Patent, leak-free anastomoses formed by day 4. All IAS magnets were expelled by day 12. All anastomoses were fully patent at 3 months with a mean diameter of 3.5 cm. The mean 3-month weight was 45 kg in bypass pigs and 78 kg in controls (P = .01). At necropsy, adhesions were absent. Histology showed full re-epithelialization across the anastomosis without fibrosis or inflammation.

CONCLUSION: Large-caliber, leak-free, foreign body-free endoscopic intestinal bypass by using IAS magnets can be safely and rapidly performed in the porcine by model using only intravenous sedation.

Предметные рубрики MeSH