MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/jcu.23084

Медицинская библиотека · Journal of clinical ultrasound : JCU · 2021

Muscle ultrasonography in detecting fasciculations: A noninvasive diagnostic tool for amyotrophic lateral sclerosis.

Rajula Rahul Reddy, Saini Jitender, Unnikrishnan Gopikrishnan, Vengalil Seena, Nashi Saraswati, Bardhan Mainak, Huddar Akshata, Chawla Tanushree, Sindhu Dodmalur Malikarjuna, Ganaraja Valakunja Harikrishna, Polavarapu Kiran, Preethish-Kumar Veeramani, Kandavel Thennarasu, Nalini Atchayaram

СтатьяПеревод в очереди

Аннотация

BACKGROUND AND

OBJECTIVES

Muscle ultrasound (MUS) is an emerging noninvasive tool to identify fasciculations in amyotrophic lateral sclerosis (ALS). We assessed the utility of MUS in detecting fasciculations in suspected ALS patients.

METHODS

Thirty-three patients (25 men) with possible (n = 7), probable (n = 12), or definite ALS according to Awaji criteria were studied. Electromyography was done in biceps brachii, quadriceps, and thoracic paraspinal muscles and MUS in biceps, triceps, deltoid, abductor-digiti-minimi, quadriceps, hamstrings, tibialis anterior, thoracic paraspinal, and tongue muscles.

RESULTS

The age at onset and illness duration was 49.73 ± 12.7 years and 13.57 ± 9.7 months, respectively. Limb-onset = 24 patients (72.7%) and bulbar-onset = 9 (27.3%). Totally 561 muscles were examined by MUS. Fasciculations were detected in 84.3% of muscles, 98.4% with and 73% without clinical fasciculations (p < 0.001). Fasciculation detection rate (FDR) by MUS was significantly higher in muscles with wasting (95.6%) than without wasting (77.6%, p < 0.001). Compared with EMG, FDR was significantly higher with MUS in quadriceps (81.8% vs. 51.5%, p = 0.002) and thoracic paraspinal muscles (75.8% vs. 42.4%, p = 0.013). The proportion of patients with definite ALS increased from 42% by clinical examination to 70% after combining EMG and MUS findings.

CONCLUSIONS

MUS is more sensitive in detecting fasciculations than electromyography (EMG) and provides a safer, faster, painless, and noninvasive alternative to EMG in detecting fasciculations in ALS.

Для цитирования: Rajula Rahul Reddy, Saini Jitender, Unnikrishnan Gopikrishnan, Vengalil Seena, Nashi Saraswati, Bardhan Mainak, Huddar Akshata, Chawla Tanushree, Sindhu Dodmalur Malikarjuna, Ganaraja Valakunja Harikrishna, Polavarapu Kiran, Preethish-Kumar Veeramani, Kandavel Thennarasu, Nalini Atchayaram. Muscle ultrasonography in detecting fasciculations: A noninvasive diagnostic tool for amyotrophic lateral sclerosis.. Journal of clinical ultrasound : JCU. 2021. DOI: 10.1002/jcu.23084.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.