MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1088/0031-9155/53/7/n02

Медицинская библиотека · Physics in medicine and biology · 2008

Arterio-venous flow between monochorionic twins determined during intra-uterine transfusion.

van Gemert Martin J C, van den Wijngaard Jeroen P H M, Lopriore Enrico, Pasman Suzanne A, Vandenbussche Frank P H A

СтатьяПеревод в очереди

Аннотация

Twin-twin transfusion syndrome (TTTS) is a severe complication of monozygotic (identical) twin fetuses sharing one single (monochorionic) placenta. TTTS is caused by a net inter-twin transfusion of blood through placental anastomoses, from one twin (the donor) to the other (the recipient), which link the two feto-placental circulations. Currently, the only reliable method to measure the net inter-twin transfusion clinically is when incomplete laser therapy of TTTS occurs and one of the twins becomes anemic and requires an intra-uterine transfusion of adult red blood cells. Then, differences between adult hemoglobin concentrations measured during the transfusion and at birth relate not only to the net inter-twin transfusion but also to the finite lifetime of the adult red blood cells. We have analyzed this situation, derived the differential equations of adult hemoglobin in the donor and recipient twins, given the solutions and given expressions relating the net inter-twin flow with clinically measured parameters. We have included single and multiple intra-uterine transfusions. In conclusion, because incomplete laser therapy occurs frequently, and some cases require an intra-uterine transfusion, this method may allow collecting a wealth of net inter-twin flow data from clinicians involved in laser therapy of TTTS. To aid to the widespread use of this method, we have presented the equations as clearly as possible in tables for easy use by others.

Для цитирования: van Gemert Martin J C, van den Wijngaard Jeroen P H M, Lopriore Enrico, Pasman Suzanne A, Vandenbussche Frank P H A. Arterio-venous flow between monochorionic twins determined during intra-uterine transfusion.. Physics in medicine and biology. 2008. DOI: 10.1088/0031-9155/53/7/n02.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.