MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1155/2022/6128832

Медицинская библиотека · Journal of ophthalmology · 2022

Characteristics of Anterior Segment in Congenital Ectopia Lentis: An SS-OCT Study.

Qi Haotian, Jin Guangming, Zou Minjie, Young Charlotte, Liu Liyan, Lian Zhangkai, Guo Dongwei, Liu Zhenzhen, Zheng Danying

СтатьяПеревод в очереди

Аннотация

PURPOSE: To investigate the characteristics of anterior chamber angle parameters in congenital ectopia lentis (CEL) patients and to evaluate the sensitivity and specificity of anterior segment parameters in distinguishing CEL from healthy controls. Setting. Zhongshan Ophthalmic Center, Guangzhou, China.

DESIGN

Cross-sectional study.

METHODS

35 CEL patients and 35 age- and sex-matched healthy controls were recruited. Axial length (AL) and anterior segment parameters including anterior chamber width (ACW), angle open distance (AOD), angle recess area (ARA), trabecular-iris space area (TISA), and trabecular-iris angle (TIA) were measured. All the above parameters and the ratio index of angle parameters, which was defined as the angle parameter value of the narrower side to that of the contralateral side, were compared between CEL and controls. Receiver operating characteristic (ROC) curves were also plotted to evaluate the diagnostic performance of anterior chamber angle parameters in CEL patients.

RESULTS

All angle parameters of the contralateral side to the dislocated lens side were significantly smaller than those of the dislocated lens side in CEL (all P < 0.05). For the diagnostic performance of anterior chamber angle parameters, the ratio index of TIAr500 combined with TIAr750 had the best diagnostic performance for CEL screening (AUC = 0.798), and TIAr500 of 0.887 and TIAr750 of 0.917 were detected to be the optimal cut-off points, representing a sensitivity of 89.8% and specificity of 68.7%.

CONCLUSION

The contralateral side to the dislocated lens side in the CEL had a narrower anterior chamber angle. TIAr500 combined with TIAr750 is the optimal combination strategy for ectopia lentis screening.

Для цитирования: Qi Haotian, Jin Guangming, Zou Minjie, Young Charlotte, Liu Liyan, Lian Zhangkai, Guo Dongwei, Liu Zhenzhen, Zheng Danying. Characteristics of Anterior Segment in Congenital Ectopia Lentis: An SS-OCT Study.. Journal of ophthalmology. 2022. DOI: 10.1155/2022/6128832.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.