MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00464-010-1507-y

Медицинская библиотека · Surgical endoscopy · 2010

Human vital amniotic membrane reduces adhesions in experimental intraperitoneal onlay mesh repair.

Petter-Puchner A H, Fortelny R H, Mika K, Hennerbichler S, Redl H, Gabriel C

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Various antiadhesive coatings have been proposed for intraperitoneal onlay meshes (IPOM). However, adhesions, mesh infections, and impaired integration remain clinically relevant problems. In this experiment, human vital amniotic membrane (AM) was tested as antiadhesive mesh coating. Vital AM complies with clinical standards of product safety.

METHODS

In this study, 24 rats were randomized to one control or two treatment groups (n=8). An uncoated polypropylene mesh (Vitamesh) was implanted using open IPOM technique and fixed with four sutures. In the treatment groups, vital AM was attached to Vitamesh by fibrin sealant fixation. The observation period was 7 and 17 days. Vitamesh fixed by suture only served as the control condition (17 days). Adhesion formation, tissue integration, and neovascularization were assessed macroscopically and histologically.

RESULTS

All the meshes in the control group elicited severe adhesions. Vital AM was highly efficient in reducing adhesions to mesh and sutures. No foreign body reaction or unfavorable immunologic response to vital AM occurred. Tissue integration and neovascularization of coated meshes were good. Fibrin sealant yielded a reliable fixation.

CONCLUSION

Human vital AM was highly effective in reducing adhesions to polypropylene mesh and sutures in experimental IPOM. No adverse effects were detected, and tissue integration of the mesh was good.

Для цитирования: Petter-Puchner A H, Fortelny R H, Mika K, Hennerbichler S, Redl H, Gabriel C. Human vital amniotic membrane reduces adhesions in experimental intraperitoneal onlay mesh repair.. Surgical endoscopy. 2010. DOI: 10.1007/s00464-010-1507-y.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.