MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1093/ehjcr/ytae523

Медицинская библиотека · European heart journal. Case reports · 2024

Transcatheter aortic valve replacement in a bicuspid aortic valve with membranous interventricular septum aneurysm communicating with aortic root: a case report.

Xi Ziwei, Yao Jing, Song Guangyuan

Клинический случайСтатьяПеревод в очереди

Аннотация

BACKGROUND

Membranous interventricular septum aneurysm (MISA) is a rare abnormality occurring in 0.3% of patients with congenital heart disease, which thereby increases anatomical complexity.

CASE SUMMARY: Transcatheter aortic valve replacement (TAVR) procedure was planned for a 71-year-old female patient from East Asia with a type 1 bicuspid aortic valve diagnosed with severe aortic stenosis by transthoracic echocardiography (TTE). Pre-procedural multidetector computed tomography (MDCT) clearly revealed an extremely horizontal aorta and a MISA originating from the sub-annulus with the upper edge extending 7.2 mm above the annulus. A probable communicating flow between the left ventricle and the aorta was confirmed by reviewing the TTE images. Moreover, there was a calcified raphe between the left- and right-coronary cusps. A downsized balloon-expandable valve (a 23 mm Sapien 3 valve with an additional 2 mL dilation) was therefore chosen and deployed with a 100/0 aortic/ventricular ratio position. The TTE post-implantation indicated a trace perivalvular leakage. The cardiac MDCT performed post-procedure, at the 6-month, and 12-month follow-ups demonstrated complete sealing and significant healing of the aneurysm.

DISCUSSION: Transcatheter aortic valve replacement utilizing a balloon-expandable valve was successfully performed for a case with membranous interventricular septum aneurysm extending above the annulus. Comprehensive imaging analysis before the procedure is crucial for TAVR with challenging anatomical conditions.

Для цитирования: Xi Ziwei, Yao Jing, Song Guangyuan. Transcatheter aortic valve replacement in a bicuspid aortic valve with membranous interventricular septum aneurysm communicating with aortic root: a case report.. European heart journal. Case reports. 2024. DOI: 10.1093/ehjcr/ytae523.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.