MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.aca.2024.343225

Медицинская библиотека · Analytica chimica acta · 2024

Rapid detection of ingested acetaminophen on face mask by ambient ionization tandem mass spectrometry.

Huang Tiao-Lai, Su Hung, Chen Jia-Cheng, Kuo Szu-Yu, Hou Chia-Yi, Shih Shu-Yu, Chu Kuo-An, Ponnusamy Vinoth Kumar, Lee Chi-Wei, Shiea Jentaie

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

A regular face mask is comprised of three layers for resisting moisture, filtration, and absorbing oral fluid, respectively. Since the polymers with different polarities are used to make the layers, a face mask can be used as a sampling tool to retain polar or non-polar chemical and biochemical substances in the exhaled breath. In this study, thermal desorption-electrospray ionization tandem mass spectrometry (TD-ESI/MS/MS), an ambient ionization mass spectrometric technique, was used to detect trace acetaminophen that were exhaled and retained on the surface of different layers in a face mask.

RESULTS

With probe sampling combined with TD-ESI/MS/MS, the acetaminophen ion signal can be detected at the mouth/nostril region of the face mask after taking the acetaminophen tablet. The experimental results were similar to previous studies for the detection of acetaminophen in blood over time using LC/MS/MS. In addition, the intensities of acetaminophen on different layers of the face mask could reveal the differing distributions of exhaled acetaminophen on each layer. To explore the distribution of acetaminophen on the face mask surface, multiple probes were used to collect samples from different locations of the face mask for analysis. The molecular mapping of acetaminophen on the face mask was rendered by scaling the analyte ion signal intensity based on a temperature color gradient. The cartography showed a higher acetaminophen ion signal distribution on the mouth and nostril regions than in other areas of the face mask.

SIGNIFICANCE: Owing to the advantages of a simple, sensitive, and non-invasive sampling approach, drug monitoring could be potentially performed to provide useful information for anti-drug of precision medicine in the future.

Для цитирования: Huang Tiao-Lai, Su Hung, Chen Jia-Cheng, Kuo Szu-Yu, Hou Chia-Yi, Shih Shu-Yu, Chu Kuo-An, Ponnusamy Vinoth Kumar, Lee Chi-Wei, Shiea Jentaie. Rapid detection of ingested acetaminophen on face mask by ambient ionization tandem mass spectrometry.. Analytica chimica acta. 2024. DOI: 10.1016/j.aca.2024.343225.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.