Effect of surgical traumas on microcirculation.
Аннотация
BACKGROUND
Adequate microcirculation in different tissues maintains the physiological function and heals surgical wounds. In any surgical procedure, the commonly used instruments are cautery, tissue forceps, and clamps. The fact that their inappropriate use produces an adverse effect on microcirculation is often not realized. By this study, we could demonstrate live, the effect of these surgical traumas.
METHODS
The study was conducted on the inferiorly based fasciocutaneous flap with a fascial extension in patients with a distal leg defect. The extended fascial flap was mounted on a glass slide and observed for live microcirculation under x160 magnification. Three methods were used: (a) cautery in low power, (b) microcrushing forceps to crush the vessels, and (c) noncrushing clamps at the base of the fascial flap.
RESULTS
It was observed that the vessels are well protected within the deep fascia. Once the fascia was pierced the current damaged the vessel wall. As the wattage was increased, it caused charring of the tissue and multiple vessels ultimately leading to cessation of blood flow. Once the vessel wall was crushed by forceps, blood extravasated in a variable intensity depending upon the size of the vessel. Clamping led to gradual slowing of blood flow with microclot formation. In certain vessels, there was discontinuity in the blood column and ultimately the blood flow stopped.
CONCLUSION
This study showed live demonstration of the effect of surgical traumas on microcirculation. It should guide the surgeons to select the use of appropriate instruments which will cause minimal damage to vascularity and thereby lead to a better surgical outcome.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.