Robot-assisted partial nephrectomy in the era of novel robotic platforms: the first european experience with the toumai® system.

Barretta Attilio, Wisz Paweł, Guidotti Alessio, Cei Francesco, Beatrici Edoardo, Rodriguez Peñaranda Natali, Prata Francesco, Pepillo Francesco, de Angelis Mario, Carl Nicolas, Brancelli Claudio, Cavarra Vincenzo, Santarelli Valerio, Lavagno Federico, Mottaran Angelo, Piazza Pietro, Bianchi Lorenzo, Hamal Robin, Lambert Edward, De Backer Pieter, De Groote Ruben, De Naeyer Geert, Schiavina Riccardo, Mottrie Alexandre

СтатьяПеревод в очереди

Аннотация

BACKGROUND

To evaluate the feasibility and safety of robot-assisted partial nephrectomy (RAPN) performed using the Toumai® robotic system in this first European experience.

METHODS

We conducted a prospective observational study including consecutive patients undergoing RAPN performed using the Toumai® robotic system at a tertiary referral robotic centre between May and December 2025. Perioperative, postoperative, functional, and pathological data were collected.

RESULTS

A total of 21 RAPN procedures were performed using the Toumai® robotic system. Median patient age was 63 years, and 15 patients (71.4%) were male. Median tumour diameter was 3.2 cm. Median total operative time was 143 min, with a median console time of 90 min . No conversions to open surgery or radical nephrectomy occurred. Two robot-related technical events (9.5%) were recorded and managed intraoperatively without clinical consequences. One postoperative complication occurred (4.8%), graded as Clavien-Dindo I. No major complications, blood transfusions, or early readmissions (<30 days) were observed. Median length of hospital stay was three days. Median estimated glomerular filtration rate (eGFR) showed a minimal change at hospital discharge, with a median ΔeGFR of -2 mL/min/1.73m2 (p = 0.2).

CONCLUSION

In this first European experience, RAPN performed using the Toumai® robotic system was feasible and safe. Further studies are required to confirm long-term outcomes and comparative performance.

Для цитирования: Barretta Attilio, Wisz Paweł, Guidotti Alessio, Cei Francesco, Beatrici Edoardo, Rodriguez Peñaranda Natali, Prata Francesco, Pepillo Francesco, de Angelis Mario, Carl Nicolas, Brancelli Claudio, Cavarra Vincenzo, Santarelli Valerio, Lavagno Federico, Mottaran Angelo, Piazza Pietro, Bianchi Lorenzo, Hamal Robin, Lambert Edward, De Backer Pieter, De Groote Ruben, De Naeyer Geert, Schiavina Riccardo, Mottrie Alexandre. Robot-assisted partial nephrectomy in the era of novel robotic platforms: the first european experience with the toumai® system.. Minimally invasive therapy & allied technologies : MITAT : official journal of the Society for Minimally Invasive Therapy. 2026. DOI: 10.1080/13645706.2026.2711930.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.