Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2023
Mechanical extraction of implantable cardioverter-defibrillator leads with a dwell time of more than 10 years: insights from a single high-volume centre.
СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Ząbek Andrzej, Boczar Krzysztof, Ulman Mateusz, Holcman Katarzyna, Kostkiewicz Magdalena, Pfitzner Roman, Dębski Maciej, Musiał Robert, Lelakowski Jacek, Małecka Barbara
Аннотация
AIMS: To analyze and compare the effectiveness and safety of transvenous lead extraction (TLE) of implantable cardioverter-defibrillator (ICD) leads with a dwell time of >10 years (Group A) vs. younger leads (Group B) using mechanical extraction systems.
METHODS AND RESULTS: Between October 2011 and July 2022, we performed TLE in 318 patients. Forty-six (14.4%) extracted ICD leads in 46 (14.5%) patients that had been implanted for >10 years. The median dwell time of all extracted ICD leads was 5.9 years. Cardiovascular implantable electronic device-related infection was an indication for TLE in 31.8% of patients. Complete ICD leads removal and complete procedural success in both groups were similar (95.7% in Group A vs. 99.6% in Group B, P = 0.056% and 95.6% in Group A vs. 99.6% in Group B, P = 0.056, respectively). We did not find a significant difference between major and minor complication rates in both groups (6.5% in Group A vs. 1.5% in Group B and 2.2% in Group A vs. 1.8% in Group B, P = 0.082, respectively). One death associated with the TLE procedure was recorded in Group B.
CONCLUSION: The TLE procedures involving the extraction of old ICD leads were effective and safe. The outcomes of ICD lead removal with a dwell time of >10 years did not differ significantly compared with younger ICD leads. However, extraction of older ICD leads required more frequent necessity for utilizing multiple extraction tools, more experience and versatility of the operator, and increased surgery costs.
METHODS AND RESULTS: Between October 2011 and July 2022, we performed TLE in 318 patients. Forty-six (14.4%) extracted ICD leads in 46 (14.5%) patients that had been implanted for >10 years. The median dwell time of all extracted ICD leads was 5.9 years. Cardiovascular implantable electronic device-related infection was an indication for TLE in 31.8% of patients. Complete ICD leads removal and complete procedural success in both groups were similar (95.7% in Group A vs. 99.6% in Group B, P = 0.056% and 95.6% in Group A vs. 99.6% in Group B, P = 0.056, respectively). We did not find a significant difference between major and minor complication rates in both groups (6.5% in Group A vs. 1.5% in Group B and 2.2% in Group A vs. 1.8% in Group B, P = 0.082, respectively). One death associated with the TLE procedure was recorded in Group B.
CONCLUSION: The TLE procedures involving the extraction of old ICD leads were effective and safe. The outcomes of ICD lead removal with a dwell time of >10 years did not differ significantly compared with younger ICD leads. However, extraction of older ICD leads required more frequent necessity for utilizing multiple extraction tools, more experience and versatility of the operator, and increased surgery costs.