MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/15533506231157438

Медицинская библиотека · Surgical innovation · 2023

The Functional Luminal Imaging Probe (FLIP): A Good Tool for Adjustment of anal Canal Dimensions During Operative Management of Fecal Incontinence.

Farag Ahmed, Mashhour Abdrabou N, Raslan Mohamed M, Khalifa Ahmed Sayed, Elbarmelgi Mohamed Yehia

СтатьяПеревод в очереди

Аннотация

PURPOSE: Fecal incontinence is a troublesome problem in the field of colorectal surgery. The main aim of this study was to adjust the anal canal resistance during operative management of anal incontinence using Endo-FLIP.

METHODS

This was a prospective cohort study held at Cairo university hospital. Hundred forty-eight incontinent patients treated by different surgical procedures were included. During the procedure the Endo-FLIP was applied to adjust the anal canal dimensions (ACL and ACD) so the ACR could be adjusted based on the flow equation. These were also assessed pre-operatively with Endo-FLIP system and the flow equation calculator. The clinical severity of the disease and outcome after surgical procedures were assessed and correlated to the physiologic parameters.

RESULTS

ACL, ACD and ACR had had significant correlations to the degree of incontinence (P < .001). ACL, ACD and ACR showed statistically significant change with primary repair and gluteus maximus transposition operations. After treatment of fecal incontinence, in good responders' group, the mean resting anal canal resistance increased significantly to 4649.05 ± 1161.49 (postoperative) while in poor responders' group it was 1919.9 ± 1077.73.

CONCLUSIONS

The Endo-flip can be used to measure the anal canal geometric parameters (ACL and ACD) and then anal canal resistance could be calculated by the flow equation - pre-and post-operatively- which help the adjustment of the surgical repair of sphincter injury in fecal incontinence patients which may improve the surgical outcome.

Для цитирования: Farag Ahmed, Mashhour Abdrabou N, Raslan Mohamed M, Khalifa Ahmed Sayed, Elbarmelgi Mohamed Yehia. The Functional Luminal Imaging Probe (FLIP): A Good Tool for Adjustment of anal Canal Dimensions During Operative Management of Fecal Incontinence.. Surgical innovation. 2023. DOI: 10.1177/15533506231157438.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.