DOI 10.1111/ases.12956

Медицинская библиотека · Asian journal of endoscopic surgery · 2021

Single incision laparoscopic repair for late-onset congenital diaphragmatic hernia using oval-shaped multichannel port device (E•Z ACCESS oval type)-2 months infantile case of Bochdalek hernia.

Ieiri Satoshi, Hino Yuko, Irie Keiko, Taguchi Tomoaki

СтатьяПеревод в очереди

Аннотация

INTRODUCTION

Late-onset congenital diaphragmatic hernia constitutes 10%-36% of congenital diaphragmatic hernias. They qualify for endoscopic treatment including both thoracoscopic and laparoscopic approaches because this type of patient is in relatively stable condition compared with neonatal cases. However, single incision laparoscopic approach has not been reported. We herein report an infantile case of late-presenting diaphragmatic hernia who underwent single incision laparoscopic repair using an oval-shaped multichannel port device.

MATERIALS AND SURGICAL TECHNIQUE: A 2 month old female infant had sudden onset dyspnea with cyanosis and was diagnosed as having left diaphragmatic hernia (Bochdalek hernia) by chest X-ray. As her respiratory condition became stable under conservative treatment using combination of decompression of the gastrointestinal tract and mild sedation, we electively planned laparoscopic repair. Preoperative enhanced computed tomography imaging found that herniated organs were stomach, spleen, pancreatic tail, small intestine and right colon. The patient also had an umbilical hernia, so we decided to perform single incision repair through this umbilical hernia. Three trocars were introduced using an oval-shaped multichannel port device and herniated organs were reduced by gentle manipulation. The defect of the diaphragm was closed by bi-hand needle driving for upper and lower limb using a stay suture. The umbilical hernia was also repaired. Postoperative course was uneventful and no recurrence was recognized.

DISCUSSION: Wider trocar separation was achieved using the oval-shaped device, making the needle driving easier to perform. By using an oval-shaped multichannel port device and ingenuity of needle driving, single incision repair of infant diaphragmatic hernia was enabled.

Для цитирования: Ieiri Satoshi, Hino Yuko, Irie Keiko, Taguchi Tomoaki. Single incision laparoscopic repair for late-onset congenital diaphragmatic hernia using oval-shaped multichannel port device (E•Z ACCESS oval type)-2 months infantile case of Bochdalek hernia.. Asian journal of endoscopic surgery. 2021. DOI: 10.1111/ases.12956.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.