Parenti Maureen B, Allen Julian, Young Lisa R, Boas Heather, Freedman Jason, Towe Christopher, Koo Jane, Myers Kasiani, Woods Jason C, Lane Adam, Gaffin Jonathan, Wong Wai, Lehmann Leslie, Urrego Fernando, Cisneros Gabriel Salinas, Abts Matthew F, Baker K Scott, Silva-Carmona Manuel, Doherty Erin, Robinson Paul D, MacMillan Margaret, Davies Stella M, Goldfarb Samuel B

Аннотация

IMPORTANCE: Oscillometry - a tidal-breathing test with potential advantages over spirometry - is not well studied prior to hematopoietic stem cell transplantation (HSCT).

OBJECTIVE: To determine whether patients awaiting HSCT have abnormal baseline oscillometry compared with controls.

METHODS: The TRANSPIRE study (NCT04098445) is a National Institutes of Health-sponsored, multicenter, prospective observational cohort of pediatric lung injury after HSCT. We performed tidal-breathing oscillometry at baseline and during follow-up in 63 children prior to HSCT across five pediatric centers and compared results to 80 control subjects. Measurements were made at various frequencies following the European Respiratory Society 2020 guidelines and included resistance (R5, R19, and R5-R19), reactance (X5 and X11), resonant frequency (Fres), and area under the reactance curve (AX). Linear regression compared TRANSPIRE baseline values to controls; mixed-effects models assessed differences between TRANSPIRE subjects, controls, and published predicted values up to two years post-HSCT.

RESULTS: All mean oscillometric parameters were normal at baseline, according to normal reference values of Ducharme. However, mean lung function in TRANSPIRE subjects was significantly different from controls, with higher respiratory system resistance (height-adjusted R5-R19, P < 0.001), and greater respiratory system stiffness and heterogeneity, with more negative height-adjusted X5 (P < 0.001) and height-adjusted X11 (P < 0.001), greater height-adjusted AX (P < 0.001), and greater height-adjusted Fres (P < 0.001). No significant changes were noted over time.

INTERPRETATION: In a multicenter pediatric HSCT cohort, baseline oscillometry differed significantly from controls, showing heterogeneous increases in small-airway resistance and respiratory-system stiffness that may elevate risk for pulmonary complications.