MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00520-005-0011-8

Медицинская библиотека · Supportive care in cancer : official journal of the Multinational Association of Supportive Care in Cancer · 2006

Atypical pulmonary embolism of port catheter fragments in oncology patients.

Surov Alexey, Jordan Karin, Buerke Michael, Persing Monica, Wollschlaeger Bettina, Behrmann Curd

СтатьяПеревод в очереди

Аннотация

GOALS OF WORK: Embolization of venous catheter fragments to the pulmonary vasculature is a very rare form of pulmonary embolism which is only sporadically reported in the literature. The incidence and clinical picture of this complication are unknown.

PATIENT AND

METHODS

In this retrospective analysis between 1999 and 2004, in our clinic, 1,014 port catheters were implanted. In this 5-year period, the patients' files were screened for the incidence of pulmonary embolism of catheter fragments and the accompanying complication rate.

MAIN

RESULTS

In 11 patients, port catheter dislodgment and embolism into the pulmonary artery occurred. In all the patients' port examination by fluoroscopy, catheter dislocation and embolization were shown. In these 11 patients, no obvious clinical signs indicating dislocation of catheter fragments into the pulmonary circulation were found. None of these patients demonstrated respiratory symptoms. Heart rate, blood pressure, respiration frequency, and even oxygen saturation were normal. In 7 of the 11 patients, malfunction of port catheter was the first indicator of catheter dislocation. In four patients, embolized catheter fragments were an incidental finding. The main cause of catheter embolization was the pinch off syndrome. All embolized catheter fragments were retrieved by a 'goose-neck' snare without complication.

CONCLUSION

These results suggest that the migration of fractured catheter into the pulmonary artery occurs in 1% of the central port catheter implantation. It is often asymptomatic, and malfunction of the catheter may be the first sign of this complication. The pinch off syndrome might be prevented by using the internal jugular vein or by implantation of the port catheter more laterally in the subclavian vein.

Для цитирования: Surov Alexey, Jordan Karin, Buerke Michael, Persing Monica, Wollschlaeger Bettina, Behrmann Curd. Atypical pulmonary embolism of port catheter fragments in oncology patients.. Supportive care in cancer : official journal of the Multinational Association of Supportive Care in Cancer. 2006. DOI: 10.1007/s00520-005-0011-8.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.