MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1001/archotol.125.1.68

Медицинская библиотека · Archives of otolaryngology--head & neck surgery · 1999

Volume-length impact of lateral jaw resections on complication rates.

Arden R L, Rachel J D, Marks S C, Dang K

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

To study the relationship between soft tissue volume loss and bone resection length following lateral segmental mandibulectomy with plate reconstruction and complication rates.

DESIGN

Retrospective case review of 31 patients (1989-1996), with average follow-up of 37.2 months, who were treated by lateral composite resection for oral cavity and/or oropharyngeal malignancy with primary reconstruction by defect-bridging plates.

SETTING

Academic tertiary care referral center.

INTERVENTIONS: Thirty patients had stainless steel and 1 patient a vitallium reconstruction plate to restore mandibular continuity. Soft tissue defects were repaired with pectoralis myocutaneous flaps (n = 25), skin grafts (n = 4), a radial forearm free flap (n = 1), or primary closure (n = 1). All patients received preoperative (n = 6) or postoperative (n = 25) radiation therapy.

MAIN OUTCOME MEASURES: Overall and hardware-related complications.

RESULTS

All 31 initial soft tissue repairs were successful. Subsequent complications occurred in 14 patients (45%), which included plate exposure (29%), loosened screws requiring hardware removal (29%), fistula (14%), local wound infection (14%), osteomyelitis (7%), and plate fracture (7%). Average time to complication was 7.7 months. Complication rates were 81% for bone defects greater than 5.0 cm, and 7% for those less than 5.0 cm. Bivariate analysis indicated bone resection lengths greater than 5.0 cm to be a significant predictor of both hardware-related (P = .02) and overall complications (P = .005), whereas soft tissue volume resections greater than 240 cm3 were found only to be marginally significant (P = .04) for overall complications.

CONCLUSION

Extirpative losses involving more than 5 cm of bone, or tissue volume greater than 240 cm3, are associated with unacceptably high complication rates when reconstructed with solid screw stainless steel plates and this warrants consideration of alternative techniques for long-term stability.

Для цитирования: Arden R L, Rachel J D, Marks S C, Dang K. Volume-length impact of lateral jaw resections on complication rates.. Archives of otolaryngology--head & neck surgery. 1999. DOI: 10.1001/archotol.125.1.68.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.