MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ahj.2023.03.016

Медицинская библиотека · American heart journal · 2023

Coronary angiography-derived index for assessing microcirculatory resistance in patients with non-obstructed vessels: The FLASH IMR study.

Huang Dong, Gong Yanjun, Fan Yongzhen, Zheng Bo, Lu Zhibing, Li Jianping, Huo Yunlong, Escaned Javier, Huo Yong, Ge Junbo

Рандомизированное исследованиеМногоцентровое исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Assessing index of microcirculatory resistance (IMR) is customarily performed using intracoronary wires fitted with sensors by at least 3 intracoronary injections of 3 to 4 mL of room-temperature saline during sustained hyperemia, which is time- and cost-consuming.

METHODS

The FLASH IMR study is a prospective, multicenter, randomized study to assess the diagnostic performance of coronary angiography-derived IMR (caIMR) in patients with suspected myocardial ischemia with nonobstructive coronary arteries using wire-based IMR as a reference. The caIMR was calculated by an optimized computational fluid dynamics model simulating hemodynamics during diastole based on coronary angiograms. TIMI frame count and aortic pressure were included in computation. caIMR was determined onsite in real time and compared blind to wire-based IMR by an independent core laboratory, using wire-based IMR ≥25 units as indicative of abnormal coronary microcirculatory resistance. The primary endpoint was the diagnostic accuracy of caIMR, using wire-based IMR as a reference, with a pre-specified performance goal of 82%.

RESULTS

A total of 113 patients underwent paired caIMR and wire-based IMR measurements. Order of performance of tests was based on randomization. Diagnostic accuracy, sensitivity, specificity, positive and negative predictive values of caIMR were 93.8% (95% CI: 87.7%-97.5%), 95.1% (95% CI: 83.5%- 99.4%), 93.1% (95% CI: 84.5%-97.7%), 88.6% (95% CI: 75.4%-96.2%) and 97.1% (95% CI: 89.9%-99.7%). The receiver-operating curve for caIMR to diagnose abnormal coronary microcirculatory resistance had area under the curve of 0.963 (95% CI: 0.928-0.999).

CONCLUSIONS

Angiography-based caIMR has a good diagnostic yield with wire-based IMR.

GOV IDENTIFIER: NCT05009667.

Для цитирования: Huang Dong, Gong Yanjun, Fan Yongzhen, Zheng Bo, Lu Zhibing, Li Jianping, Huo Yunlong, Escaned Javier, Huo Yong, Ge Junbo. Coronary angiography-derived index for assessing microcirculatory resistance in patients with non-obstructed vessels: The FLASH IMR study.. American heart journal. 2023. DOI: 10.1016/j.ahj.2023.03.016.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.