MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jsams.2025.10.005

Медицинская библиотека · Journal of science and medicine in sport · 2025

Validity of thorax-worn GPS heart rate data during continuous incremental and intermittent running.

Fary Thomas, Duthie Grant, Campbell Patrick, Jennings Jacob, Ballard David, Speranza Michael, Johnston Rich

СтатьяВалидационное исследованиеПеревод в очереди

Аннотация

OBJECTIVES

To determine the level of agreement between Catapult Vector S7 and Polar H10 for measuring heart rate (HR) during continuous incremental and intermittent running.

DESIGN

Concurrent validity study.

METHODS

Twenty participants (n = 10 males, 10 females; age = 25.7 ± 4.9 years) completed a continuous incremental and intermittent running protocol on a motorised treadmill with HR measured wearing Catapult Vector S7 and Polar H10 devices. The continuous protocol involved incremental increases in speed at a fixed 1 % incline until at least 90 % of age-predicted heart rate max (HRmax) was reached. The intermittent protocol was completed following a standardised recovery period. Coefficient of determination (R2), root mean square error (RMSE), mean absolute percentage error (MAPE), mean bias, and 95 % limits of agreement (LoA) were used to measure agreement between the two devices.

RESULTS

Near-perfect agreement (R2 = 0.99 for all participants) between the two devices was observed for the continuous and intermittent protocols. The RMSE was low for all participants, measuring 1.6 beats per minute (bpm) during the continuous protocol and 1.2 bpm during the intermittent protocol. No systematic bias was observed in either protocol when grouped by sex. Although females showed slightly higher RMSE values in both the continuous (2.2 vs 0.7 bpm) and intermittent protocols (1.5 vs 0.8 bpm), the Vector S7 validity remained high.

CONCLUSIONS

The Catapult Vector S7, in combination with Vector Elite 2.3 Vest, represents a highly valid alternative to chest-worn straps in measuring HR during high-intensity exercise involving continuous and intermittent running.

Для цитирования: Fary Thomas, Duthie Grant, Campbell Patrick, Jennings Jacob, Ballard David, Speranza Michael, Johnston Rich. Validity of thorax-worn GPS heart rate data during continuous incremental and intermittent running.. Journal of science and medicine in sport. 2025. DOI: 10.1016/j.jsams.2025.10.005.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.