MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.foodchem.2024.140380

Медицинская библиотека · Food chemistry · 2024

A portability self-powered sensor facilitates sensitive Cd2+ detection: Dual mechanism and three quantitative mode.

Xu Jing, Luo Xinqi, Cao Chengyuan, Ling Ge, Zheng Yue, Zhang Wei

СтатьяОценочное исследованиеПеревод в очереди

Аннотация

As a common heavy metal contaminant, Cd2+ has adverse effects on food safety and consumer health. It is very important for human health to realize highly sensitive Cd2+ detection methods. The self-powered sensing system based on enzyme biofuel cells (EBFCs) does not need an external power supply, which can simplify the experimental equipment and has great application value in portable detection. Thus, the biosensor is innovatively integrated into the screen-printed electrode to construct a new type of portable sensor suitable for on-site and real-time Cd2+ detection. Hybridization chain reaction (HCR) combined with the Cd2+-dependent deoxyribose (DNAzyme) signal amplification strategy is used to enhance the detection sensitivity while specifically recognizing the Cd2+. Moreover, the self-powered sensor combines with smartphones to realize quantitative Cd2+ detection without other instruments and has the characteristic of Effectively improving the hazard detection technology is essential to ensure food safety. Portability, simplicity, and speed are suitable for real-time Cd2+ detection in the field. The dual mechanism and three quantitative modes combining colorimetric and two electrical signals output modes are adopted to realize the visualization and accurate detection. A series of research results confirm that this strategy is of great significance to strengthen the development of intelligent Cd2+ technology, expand the application of self-powered sensing technology, and improve the safety detection system.

Для цитирования: Xu Jing, Luo Xinqi, Cao Chengyuan, Ling Ge, Zheng Yue, Zhang Wei. A portability self-powered sensor facilitates sensitive Cd2+ detection: Dual mechanism and three quantitative mode.. Food chemistry. 2024. DOI: 10.1016/j.foodchem.2024.140380.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.