MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3390/ijerph20010297

Медицинская библиотека · International journal of environmental research and public health · 2022

Application of High-Performance Liquid Chromatography Combined with Fluorescence Detector and Dispersive Liquid-Liquid Microextraction to Quantification of Selected Bisphenols in Human Amniotic Fluid Samples.

Szubartowski Szymon, Tuzimski Tomasz

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Bisphenol A (BPA) is a widely produced chemical worldwide found in numerous everyday products. Its endocrine-disrupting properties and omnipresence have aroused concern and led to several restrictions on its use. These restrictions and growing public awareness about the toxicity of BPA have resulted in market products labeled "BPA-free", with BPAs often being replaced by other bisphenols. This is why constant biomonitoring of bisphenol levels in various body fluids and tissues is essential. In this study, we propose the use of simple, cost-effective high-performance liquid chromatography coupled with the fluorescence detector (HPLC-FLD) method for the determination of simultaneously selected bisphenols in amniotic fluid. For the sample preparation, a fast, simple, and "green" dispersive liquid-liquid microextraction (DLLME) method was used, achieving mean recovery values in the range of 80.9-115.9% with relative standard deviations below 12% for all analytes. Limits of quantification (LOQs) determined in the amniotic fluid matrix ranged from 6.17 to 22.72 ng/mL and were obtained from a calibration curve constructed using least-squares linear regression analysis for all cases. The presented sample preparation procedure can be easily adopted for LC-MS analysis.

Для цитирования: Szubartowski Szymon, Tuzimski Tomasz. Application of High-Performance Liquid Chromatography Combined with Fluorescence Detector and Dispersive Liquid-Liquid Microextraction to Quantification of Selected Bisphenols in Human Amniotic Fluid Samples.. International journal of environmental research and public health. 2022. DOI: 10.3390/ijerph20010297.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.