DOI 10.1016/j.rmed.2012.12.022
Comparison of changes in lung function measured by plethymography and IOS after bronchoprovocation.
Аннотация
AIM: Lung function tests are essential for the diagnosis and management of bronchial asthma. Impulse oscillation (IOS) system is an alternative way to measure lung mechanics for some patients. We investigated the relative sensitivities of IOS, body plethysmography and spirometry in detecting allergen- and methacholine-induced bronchoconstriction.
METHOD: Twenty-two subjects had single allergen inhalation and 8 subjects had 3 methacholine challenges. The tests were stopped when FEV1 fell by 20%. Lung function was measured using IOS (R5, R20, R5-R20, X5, AX, fres), plethysmography (sRaw, sGaw, FRC, lung volumes) and spirometry (FEV1, FVC, PEF, FEF50%) during inhalation challenges, and expressed as percent change from pre-challenge baseline.
RESULTS
All subjects were non-smoking adults with mild allergic asthma. Following allergen challenges, the most sensitive IOS index was R5-R20 and the most sensitive plethysmography and spirometry measurements were sRaw, sGaw and FEF50%. Following methacholine challenge the most sensitive IOS index was AX, the most sensitive plethysmography measurement was sRaw. Overall, IOS (R5-R20, AX, X5Hz) proved to be more sensitive than plethysmography and spirometry measurements following allergen-induced and methacholine-induced bronchoconstriction.
CONCLUSION
Our result shows that IOS is more sensitive than other lung function tests following allergen and methacholine challenge. In addition, IOS can act as an alternative measurement technique of airway resistance and obstruction in patients where manoeuvres involved in plethysmography and spirometry prove difficult to perform.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.