Endotracheal Tube Size Estimation in Paediatric Patients: A Head-to-head Comparison of Accuracy Between Ultrasonography and Age-based Formula.
Аннотация
OBJECTIVE
In the paediatric population, the selection of an appropriately sized endotracheal tube (ETT) is extremely important not only to ensure adequate ventilation but also to avoid post-extubation stridor and stenosis. Conventionally, formulas based on age, height, or weight are used to determine the most appropriate size. In this study, we compared ultrasonography (USG) and age-based formula for predicting the best microcuff ETT size in paediatric patients aged 1-5 years.
METHODS
One hundred eighteen patients, aged 1 to 5 years, with American Society of Anesthesiologists, classifications of I or II, were included. After standard general anaesthesia protocols, the subglottic diameter was assessed by USG. Intubation was performed using ETT size according to age-based formula. The best clinical fit was determined after the leak test. The internal and external diameters of the ETTs were predicted by both methods and correlated with the best-fit ETT sizes used during the procedures using Pearson's correlation. Cohen's kappa was used for statistical agreement between two methods.
RESULTS
USG had a significantly higher correlation with the best-fit model as compared to the age-based formula, with 99.2% and 77.1% agreement rates. The best-fit ETT showed a better correlation with the USG-guided estimate (r = 0.994, P < 0.001). The Cohen's Kappa value of 0.986 showed a statistically significantly higher agreement between USG-guided estimate and best-fit ETT.
CONCLUSION
USG-guided estimation of subglottic diameter is a better predictor for optimally sized microcuff ETT than the age-based formula in the paediatric age group of 1-5 years. 22% of tube changes could have been prevented with ultrasound-guidance as a primary approach for estimating ETT size.