BACKGROUND

Hypersensitivity pneumonitis (HP) is an interstitial lung disease (ILD) caused by repeated exposure to inhaled antigens, leading to small airway and parenchymal inflammation. Diagnosis is based on a detailed clinical history, chest imaging and invasive tests such as bronchoalveolar lavage. Distinguishing HP from other ILDs is challenging. Respiratory oscillometry, a novel pulmonary function test (PFT), is highly sensitive to small airway abnormalities. Oscillometry measurement of reactance is strongly correlated with gender-age-physiology score, a prognostic tool used to predict mortality and disease severity in idiopathic pulmonary fibrosis (IPF).

OBJECTIVE

To determine if oscillometry and standard PFT patterns are different in HP and IPF.

METHODS

39 HP (79.5% with fibrotic HP) were enrolled from October 2022 to December 2023 for oscillometry before clinically-indicated standard PFTs and compared with 39 age-matched and sex-matched patients with IPF who also had same day oscillometry and standard PFTs. The main oscillometry metrics of interest were R5-19 (the difference in resistance from 5 to 19 Hz, a metric of small airway function and ventilatory inhomogeneity that increases with worsening respiratory mechanics), X5 (reactance at 5 Hz) which primarily reflects respiratory elastance and AX (area of reactance), a summative measure of the respiratory system stiffness across a range of frequencies, that behaves similarly but in opposite direction to X5.

RESULTS

Patients with HP exhibited higher residual volume/total lung capacity (RV/TLC), lower per cent predicted (%) forced expiratory volume in 1 s (FEV1) and % predicted forced vital capacity (FVC) than IPF (p<0.05) while FEV1/FVC and %TLC were similar. Oscillometry showed higher R5-19 in HP. RV/TLC ratio correlated with AX (r2=0.72), X5 (r2=0.66) and R5-19 (r2=0.64).

CONCLUSION

Gas trapping (RV/TLC>0.40) is a feature of HP not observed in IPF. The strong correlations of RV/TLC with AX, X5 and R5-19 suggest that oscillometry can provide non-invasive markers of small airway obstruction in HP that can differentiate it from IPF.

Для цитирования: Wu Joyce K Y, Xu Jessica Jia-Ni, Numakura Tadahisa, Ryan Clodagh M, McInnis Micheal Chad, Binnie Matthew, Shapera Shane, Fisher Jolene H, Hantos Zoltán, Chow Chung-Wai. Standard pulmonary function tests and respiratory oscillometry patterns in hypersensitivity pneumonitis and idiopathic pulmonary fibrosis.. BMJ open respiratory research. 2025. DOI: 10.1136/bmjresp-2025-003600.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.