MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jse.2020.04.026

Медицинская библиотека · Journal of shoulder and elbow surgery · 2020

Glenohumeral joint lavage does not affect clinical outcomes in open reduction and internal fixation of displaced intracapsular proximal humeral fractures: a prospective, randomized, double-blinded trial.

Biermann Niklas, Schirren Mirjam, Siebenbürger Georg, Fleischhacker Evi, Helfen Tobias, Böcker Wolfgang, Ockert Ben

СтатьяРандомизированное исследованиеПеревод в очереди

Аннотация

BACKGROUND

This prospective, randomized, and double-blinded trial evaluates the effect of intraoperative glenohumeral joint lavage in open reduction and internal fixation of displaced intracapsular proximal humeral fractures.

METHODS

Between January 2016 and April 2018, 86 patients (mean age: 65.2 ± 16.3 years) with a displaced intracapsular proximal humeral fracture were treated by open reduction and internal fixation using locking plates. Patients were randomized to either locked plating followed by intraoperatively performed glenohumeral joint lavage (group L, n = 36) or locked plating without the lavage (group NL, n = 36). Functional outcome assessment included range of shoulder motion, strength, and the Constant score, obtained 6 weeks, 3 months, 6 months, and 12 months postoperatively. A total of 62 shoulders could be reviewed for final investigation (86% follow-up).

RESULTS

One year after open reduction and internal fixation, the mean Constant score was 70 ± 14 (group L, n = 31) compared with 73 ± 14 (group NL, n = 31, P = .272). The mean forward flexion and abduction in group L was 134 ± 33 and 128 ± 33 as compared with 139 ± 32 and 135 ± 32 in group NL, respectively (P = .538, P = .427). The mean external rotation was 40 ± 16 (group L) compared with 44 ± 16 (group NL) (P = .210). The overall complication rate was 9.6% and did not differ significantly between the groups (P = .321). In group L, there were 2 cases of avascular necrosis (6.5%) and 1 case of secondary displacement (3.2%). In group NL, 1 case of avascular necrosis (3.2%) and 1 case of secondary displacement were noted (3.2%, P = .742).

CONCLUSION

The results of this study do not demonstrate a need for glenohumeral joint lavage in open reduction and internal fixation of displaced intracapsular proximal humeral fractures with regard to shoulder function at 1-year follow-up.

Для цитирования: Biermann Niklas, Schirren Mirjam, Siebenbürger Georg, Fleischhacker Evi, Helfen Tobias, Böcker Wolfgang, Ockert Ben. Glenohumeral joint lavage does not affect clinical outcomes in open reduction and internal fixation of displaced intracapsular proximal humeral fractures: a prospective, randomized, double-blinded trial.. Journal of shoulder and elbow surgery. 2020. DOI: 10.1016/j.jse.2020.04.026.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.