MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1080/15376516.2026.2652433

Медицинская библиотека · Toxicology mechanisms and methods · 2026

Comparative stability assessment of synthetic cannabinoids in dry blood spots and blood using UHPLC-MS/MS: implications for forensic applications.

Tusiewicz Kaja, Szpot Paweł, Zawadzki Marcin

СтатьяСравнительное исследованиеПеревод в очереди

Аннотация

OBJECTIVES

Synthetic cannabinoids are the most numerous group of new psychoactive substances (NPSs) in Europe. The diversity and quantity of newly emerging synthetic cannabinoids make it difficult to monitor intoxications with these compounds, especially in view of their stability after biological material collection.

METHODS

In this study, 17 NPSs were analyzed to determine their stability in whole blood and dry blood spots (DBSs). The samples were stored at room temperature (DBS), 4 °C (DBS and whole blood), and -20 °C (whole blood). Analyses were performed using ultra-high-performance liquid chromatography coupled with tandem mass spectrometry. The stability study lasted 365 days, monitoring the degradation rate of analytes. Moreover, the effect of chemical structure on analyte stability was assessed.

RESULTS

Results proved that the stability of analytes depended on both storage conditions and their chemical structure. Four compounds showed better long-term stability in DBS samples, whereas seven of the tested compounds exhibited significantly better long-term stability in whole blood samples.

CONCLUSIONS

Studies indicate a strong correlation between the stability of synthetic cannabinoids and both their chemical structure and storage conditions. DBS cards can provide equal or enhanced stability compared to whole blood, which makes it advisable to collect biological material in both forms to help maximize analytical options in forensic and toxicological investigations.

Для цитирования: Tusiewicz Kaja, Szpot Paweł, Zawadzki Marcin. Comparative stability assessment of synthetic cannabinoids in dry blood spots and blood using UHPLC-MS/MS: implications for forensic applications.. Toxicology mechanisms and methods. 2026. DOI: 10.1080/15376516.2026.2652433.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.