MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1093/ejcts/ezr258

Медицинская библиотека · European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery · 2012

Stent implantation in the arterial duct of the newborn with duct-dependent pulmonary circulation: single centre experience from Turkey.

Odemis Ender, Haydin Sertac, Guzeltas Alper, Ozyilmaz Isa, Bilici Meki, Bakir Ihsan

Оценочное исследованиеСтатьяПеревод в очереди

Аннотация

OBJECTIVES

Implantation of stents into the ductus arteriosus is an alternative treatment to palliative or corrective cardiac surgery in newborns with duct-dependent pulmonary circulation, although the use of this technique for congenital heart disease is limited.

METHODS

Between April 2010 and June 2011, 13 patients underwent patent ductus arteriosus stenting after full assessment by echocardiogram and angiogram, two of patients had pulmonary atresia (PA) and ventricular septal defect (VSD), six patients had PA with intact ventricular septum (IVS), four patients had critical pulmonary stenosis with IVS and one single ventricle physiology with PA and four patients had radiofrequency-assisted perforation of the pulmonary valve at the same time. All procedures were retrograde through the femoral artery, except one, which was by the femoral vein approach.

RESULTS

The mean age and weight during intervention were 10.5±5.7 days and 3.1±0.4 kg, respectively. The mean of procedure and scopy time, time of stay in intensive care, total out-of-hospital and total follow-up time were 138.88±67.11 min; 40.32±25.86 min; 4.88±6.07 days; 11.00±6.89 days and 86.40±73.21 days, respectively. The mean of the radiation amount was 1054.27±1106.91 cGy/cm2. The mean of saturation before and after intervention were 64.44±5.83; 81.88±6.95%, respectively. Procedure-related deaths were observed in two patients. The causes of death were pulmonary haemorrhage (n=1) and retroperitoneal haemorrhage (n=1). Two patients also died after discharge before surgery due to sepsis (n=1) and aspiration pneumonia (n=1). Eight of 13 patients achieved stent patency during 6 months of follow up and re-stenosis developed in one patient (1/8; 12.5%) who had undergone a Glenn operation at 4.5 months of age.

CONCLUSIONS

Ductal stenting is a practicable, effective, safer and less invasive method compared palliative or corrective surgery. Patients with ductal stenting have growth of the pulmonary artery which provides additional time for surgical repair. Our data suggested that ductal stenting should be considered as a first treatment step in newborns with duct-depended pulmonary circulation. However, long-term palliation without stent re-stenosismight still be a concern especially in patients with hypoplastic pulmonary arteries.

Для цитирования: Odemis Ender, Haydin Sertac, Guzeltas Alper, Ozyilmaz Isa, Bilici Meki, Bakir Ihsan. Stent implantation in the arterial duct of the newborn with duct-dependent pulmonary circulation: single centre experience from Turkey.. European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery. 2012. DOI: 10.1093/ejcts/ezr258.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.