MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1001/jamaophthalmol.2013.5595

Медицинская библиотека · JAMA ophthalmology · 2013

Follow-up study of more than 15 years of an angle-supported phakic intraocular lens model (ZB5M) for high myopia: outcomes and complications.

Alio Jorge L, Abbouda Alessandro, Peña-Garcia Pablo, Huseynli Samira

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

IMPORTANCE

This study confirmed the long-term outcomes of the ZB5M phakic intraocular lens (PIOL).

OBJECTIVE

To evaluate the potential long-term risk associated with ZB5M PIOL implantation.

DESIGN, SETTING, AND

PARTICIPANTS

A retrospective, nonrandomized, consecutive cohort study of a total of 208 eyes implanted with ZB5M PIOLs at VISSUM Corporación Oftalmológica de Alicante between 1990 and 1996 identified through surgical records (208 eyes of 123 patients); 50 of these patients (97 eyes) had available records and follow-up.

INTERVENTION: ZB5M PIOL implantation.

MAIN OUTCOMES AND MEASURES: To evaluate the incidence and onset of each complication during the follow-up and risk factors and causes for loss of visual acuity.

RESULTS

Mean (SD) preoperative spherical equivalent refraction was -19.36 (6.7) diopters and at the end of follow-up, it was -1.4 (2.6) diopters. Mean (SD) best-corrected visual acuity at the preoperative visit was 0.35 (0.2) decimal and at the end of follow-up, 0.56 (0.3) decimal. Mean (SD) endothelial cell density preoperatively and at the end of follow-up was 2783 (787) cells/mm(2) and 1921 (672) cells/mm(2), respectively. The incidence of cataract during the follow-up was 0.010 eye-year (EY); cornea decompensation, 0.001 EY; ocular hypertension, 0.008 EY; pupil ovalization, 0.020 EY; uveitis, 0.001 EY; and retinal detachment, 0.002 EY.

CONCLUSIONS AND RELEVANCE: To our knowledge, this is the first study that describes the long-term outcomes and complications of ZB5M PIOLs and suggests increasing the postoperative follow-up examinations in patients older than 40 years, analyzing anterior chamber modifications, and recommends PIOL explantation in cases of an increase in the crystalline size.

Для цитирования: Alio Jorge L, Abbouda Alessandro, Peña-Garcia Pablo, Huseynli Samira. Follow-up study of more than 15 years of an angle-supported phakic intraocular lens model (ZB5M) for high myopia: outcomes and complications.. JAMA ophthalmology. 2013. DOI: 10.1001/jamaophthalmol.2013.5595.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.