MedElevator Войти в исследования
← Поиск публикаций

DOI 10.5455/medarh.2021.75.45-49

Медицинская библиотека · Medical archives (Sarajevo, Bosnia and Herzegovina) · 2021

Detecting Fetal Central Nervous System Anomalies Using Magnetic Resonance Imaging and Ultrasound.

Linh Le Tuan, Duc Nguyen Minh, Nhung Nguyen-Thi Hong, My Thieu-Thi Tra, Luu Doan Tien, Lenh Bui Van

Сравнительное исследованиеСтатьяПеревод в очереди

Аннотация

BACKGROUND

Most fetal abnormalities can be detected on ultrasound, the evaluation of fetal CNS abnormalities can be limited by various factors, including obesity, polyhydramnios, multiple pregnancies, and increased cranial ossification during the third trimester.

OBJECTIVE

This study aimed to evaluate the ability to detect fetal central nervous system (CNS) anomalies using in utero magnetic resonance imaging (iuMRI) and ultrasound (US) techniques.

METHODS

This prospective study was approved by the institutional review board (Ref: 2968/QĐ-ĐHYHN dated 11 July 2019), and the requirement to obtain the informed consent of patients was waived. This study included 66 fetuses with diagnosed or suspected CNS abnormalities based on the results of a prenatal screening US performed at the antenatal diagnosis center of the Central Obstetrics and Gynecology Hospital. All pregnant women with a suspected diagnosis of abnormal fetal CNS on US underwent 1.5-Tesla iuMRI within 14 days of the US at Hanoi Medical University Hospital between June 2019 and June 2020. Cohen's kappa coefficient (κ) was used to determine the agreement between US and iuMRI findings.

RESULTS

A total of 66 pregnant women were examined, including 66 fetuses, for which 79 abnormalities were detected by US and 98 abnormalities were detected by iuMRI. The average gestational age was 29 weeks and 6 days. The comparison of iuMRI and US findings revealed similar diagnoses for 71 abnormalities (67%) and different diagnoses for 35 abnormalities (33%). The level of agreement between US and iuMRI was almost perfect for ventriculomegaly and cystic lesions, with κ values 0.87 and 0.84, respectively. The level of agreement between US and iuMRI was the weakest for hemorrhage, with a κ value 0 (no agreement), and cortical abnormalities, with a κ value of 0.46 (weak agreement).

CONCLUSION

The level of agreement between US and iuMRI diagnoses was almost perfect for the detection of ventriculomegaly and was weakest for the detection of hemorrhage and cortical abnormalities, which were abnormalities detected by iuMRI but not by ultrasound.

Для цитирования: Linh Le Tuan, Duc Nguyen Minh, Nhung Nguyen-Thi Hong, My Thieu-Thi Tra, Luu Doan Tien, Lenh Bui Van. Detecting Fetal Central Nervous System Anomalies Using Magnetic Resonance Imaging and Ultrasound.. Medical archives (Sarajevo, Bosnia and Herzegovina). 2021. DOI: 10.5455/medarh.2021.75.45-49.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.