MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/wnp.0b013e31819f9067

Медицинская библиотека · Journal of clinical neurophysiology : official publication of the American Electroencephalographic Society · 2009

Neurophysiologic intraoperative monitoring during surgery for tethered cord syndrome.

Khealani Bhojo, Husain Aatif M

СтатьяОбзорПеревод в очереди

Аннотация

Tethered cord syndrome (TCS) occurs when the distal spinal cord is adherent to inelastic tissue. This results in sensorimotor deficits in the lower extremities, bowel and bladder dysfunction, and musculoskeletal deformities. Tethered cord syndrome is often found in childhood, but may be first noticed in adults as well. The symptoms are usually progressive unless halted by surgical correction of the spinal cord tethering. Surgery for TCS can be complicated by inadvertent injury to nerves that are either embedded in the tether or in close proximity to it. In an attempt to reduce this iatrogenic injury, neurophysiologic intraoperative monitoring is used to identify neural structures in the surgical field and reduce the risk of injury. Many neurophysiologic intraoperative monitoring paradigms have been used in TCS surgery, including free running and stimulated electromyography of the muscles of the lower extremities, external anal and external urethral sphincter electromyography, tibial, clitoral, and dorsal penile somatosensory evoked potentials, and bulbocavernosus reflex testing. It is widely believed that neurophysiologic intraoperative monitoring helps reduce morbidity of TCS surgery, but data supporting this are limited. This article will review the various neurophysiologic intraoperative monitoring paradigms that can be used in TCS surgery and discuss the data supporting the use of these paradigms.

Для цитирования: Khealani Bhojo, Husain Aatif M. Neurophysiologic intraoperative monitoring during surgery for tethered cord syndrome.. Journal of clinical neurophysiology : official publication of the American Electroencephalographic Society. 2009. DOI: 10.1097/wnp.0b013e31819f9067.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.