MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.injury.2003.08.008

Медицинская библиотека · Injury · 2004

Anatomical considerations for percutaneous proximal humeral fracture fixation.

Kamineni S, Ankem H, Sanghavi S

СтатьяПеревод в очереди

Аннотация

PURPOSE: To investigate the hypothesis that percutaneous wire fixation of proximal humeral fractures is prone to regional neurovascular injury.

MATERIALS AND

METHODS

40 cadaveric shoulders had percutaneous wires inserted from anterior and lateral humeral shaft entry points into the humeral head. The shoulders were then dissected to identify the neurovascular structures in this area.

RESULTS

The axillary nerve trunk and posterior circumflex humeral artery were found to be within the field of dissection. The axillary nerve was damaged on three occasions by the lateral wires, two of which were direct nerve penetrations. The anterior wires caused a single perineural injury of a terminal branch. The main neurovascular leash was 57 mm (range 35-70 mm) from the acromion tip laterally and 51 mm (range 35-85 mm) anteriorly, with a width of 6 mm (range 4-13 mm) laterally, and 12 mm (range 7-15 mm) anteriorly.

CONCLUSIONS

Percutaneous wire stabilisation is an attractive fixation option but this study highlights the close proximity of the important neurovasculature. Such fixation should be performed utilising a limited open approach, with dissection to bone under direct vision, with the subsequent use of a drill-sleeve for soft-tissue protection.

Для цитирования: Kamineni S, Ankem H, Sanghavi S. Anatomical considerations for percutaneous proximal humeral fracture fixation.. Injury. 2004. DOI: 10.1016/j.injury.2003.08.008.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.