MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00402-012-1642-0

Медицинская библиотека · Archives of orthopaedic and trauma surgery · 2012

Functional results and quality of life after bilateral scaphoid reconstruction: a case series.

Corsten Marcus, Heffinger Christian, Kolios Leila, Lehnhardt Marcus, Bickert Berthold, Hirche Christoph

СтатьяПеревод в очереди

Аннотация

Unilateral scaphoid non-union remains a major problem, which can lead to major functional limitations. Until now there is no evidence of outcome of the rare case of bilateral scaphoid non-unions and in how far two-stage bilateral reconstruction affects functional results and the quality of life. Between 1997 and 2010, altogether four bilateral scaphoid non-unions were treated in the centre and retrospectively analyzed. The mean follow-up was performed 36.8 months after reconstruction. The measures included analysis of patient data, analysis of functional measures and quality of life after follow-up. The reconstructions were performed with implantation of a free, non-vascularized iliac crest bone graft (4), osteosynthesis with implantation of a pedicled vascularized bone graft (3) and osteosynthesis with cancellous bone graft (1). The mean range of motion of the wrist was extension/flexion 111.3°. The average grip strength by JAMAR dynamometer showed right versus left sight 32.7 kg (±3.5) versus 33.7 (±2.9). The evaluation of the DASH score resulted in 11.6 (±12.5), the SF36 scale in 87.1 (±9.2) points. The present case series for the first time demonstrated functional mid-term results of the rare event of bilateral scaphoid reconstruction after non-union. With respect to the impact on one affected hand, functional results, DASH score and quality of life are excellent and thus justify good prognosis in patient education after injury.

Для цитирования: Corsten Marcus, Heffinger Christian, Kolios Leila, Lehnhardt Marcus, Bickert Berthold, Hirche Christoph. Functional results and quality of life after bilateral scaphoid reconstruction: a case series.. Archives of orthopaedic and trauma surgery. 2012. DOI: 10.1007/s00402-012-1642-0.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.