DOI 10.1093/rpd/ncad128

Медицинская библиотека · Radiation protection dosimetry · 2023

Postirradiation temperature influences DSB repair and dicentric chromosome formation-potential impact for dicentric chromosome analysis in interlaboratory comparisons.

Beinke Christina, Port Matthias, Scherthan Harry

СтатьяПеревод в очереди

Аннотация

The objective was to investigate the influence of different pre-storage temperatures in the dicentric chromosome analysis (DCA) protocol (22°C vs. 37°C) by using γ-H2AX + 53BP1 foci as a marker for deoxyribonucleic acid (DNA) double-strand break (DSB) damage induction and repair and the formation of dicentric chromosomes as a result of mis-repair. Repair of γ-H2AX + 53BP1 DSB foci was absent in samples that were incubated for 2 h at 22°C after exposure of 0.5 and 1.2 Gy. When 0.5- and 1.2-Gy-exposed samples were incubated at 37°C for 2 h, there was an average decline of 31 and 52% of DSB foci, respectively. This indicated that DNA repair occurred. There was a 27% decrease in dicentric chromosome yield at 1.2 Gy and a 15% decrease at 3.5 Gy after post-irradiation incubation for 2 h at 37°C relative to the observed dicentric frequencies at 22°C. Recommended to re-phase: our data suggested that there were more open DSBs after a 2-h incubation at 22°C, which contributed to more mis-repair and dicentric formation from the start of culture. Our findings are corroborated by publications showing that lesion interaction based on enzymatic activity is suppressed below 21°C. As such temperature variations can be a source of variation in DCA during interlaboratory comparison studies, we propose to establish a common guide for the standardisation of pre-culture conditions in cytogenetic dosimetry proficiency testing.

Для цитирования: Beinke Christina, Port Matthias, Scherthan Harry. Postirradiation temperature influences DSB repair and dicentric chromosome formation-potential impact for dicentric chromosome analysis in interlaboratory comparisons.. Radiation protection dosimetry. 2023. DOI: 10.1093/rpd/ncad128.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.