Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Schneider Rick, Randolph Gregory W, Sekulla Carsten, Phelan Eimear, Thanh Phuong Nguyen, Bucher Michael, Machens Andreas, Dralle Henning, Lorenz Kerstin
Аннотация
BACKGROUND: Conventional intraoperative nerve monitoring, predicated on intermittent stimulation, can predict recurrent laryngeal nerve (RLN) palsy only after the damage has been done.
METHODS: Fifty-two patients (52 nerves at risk) who underwent continuous intraoperative nerve monitoring (CIONM) for thyroid surgery via vagus nerve stimulation had their electromyographic (EMG) tracings recorded and correlated with surgical maneuvers and postoperative RLN function.
RESULTS: There was 1 imminent loss of signal (LOS) with intraoperative signal recovery and there were 4 losses of signal with corresponding unilateral transient RLN palsy. When EMG amplitude decreased >50% and EMG latency increased >10%, LOS and postoperative RLN palsy were noted in 4 of 8 patients (50%) who had multiple combined events. In 9 of 13 patients (70%) who developed adverse EMG changes, modification of the causative surgical maneuver resulted in recovery of those EMG changes and aversion of impending RLN palsy.
CONCLUSION: CIONM reliably signaled impending nerve injury, enabling immediate corrective action.
METHODS: Fifty-two patients (52 nerves at risk) who underwent continuous intraoperative nerve monitoring (CIONM) for thyroid surgery via vagus nerve stimulation had their electromyographic (EMG) tracings recorded and correlated with surgical maneuvers and postoperative RLN function.
RESULTS: There was 1 imminent loss of signal (LOS) with intraoperative signal recovery and there were 4 losses of signal with corresponding unilateral transient RLN palsy. When EMG amplitude decreased >50% and EMG latency increased >10%, LOS and postoperative RLN palsy were noted in 4 of 8 patients (50%) who had multiple combined events. In 9 of 13 patients (70%) who developed adverse EMG changes, modification of the causative surgical maneuver resulted in recovery of those EMG changes and aversion of impending RLN palsy.
CONCLUSION: CIONM reliably signaled impending nerve injury, enabling immediate corrective action.