A clinical comparison of safety and efficacy in phacoemulsification with versus without ophthalmic viscoelastic device.

Kugu Suleyman, Erdogan Gurkan, Sahin Sevim M, Ozerturk Yusuf

Сравнительное исследованиеСтатьяРандомизированное исследованиеПеревод в очереди

Аннотация

PURPOSE: To evaluate in a comparative manner the safety and efficacy of 1.0% sodium-Hyaluronate used during capsulorhexis and intraocular lens (IOL) implantation in phacoemulsification surgery.

MATERIALS AND

METHODS

1.0% sodium-Hyaluronate, which is commonly used as one of the ophthalmic viscoelastic devices, was compared to intraocular irrigating solution, which can bring up these effects. In addition, the effect of both methods on occurring corneal endothelial cell (CEC) loss was investigated.

RESULTS

Each group comprised 19 eyes. The mean preoperative CEC density was 2525.68 ± 181.85 in Group H and 2514.16 ± 174.59 in Group V; no statistically significant difference was found between the groups (p > 0.05). Preoperative and postoperative first and twelfth week CEC densities were 2438.21 ± 198.12 (p < 0.001) and 2390.74 ± 202.31, respectively, in group H (p < 0.001). Preoperative and postoperative first and twelfth week CEC densities were 2415.32 ± 197.24 (p < 0.001) and 2353.47 ± 212.69 in group V (p < 0.001). Compared with preoperative values, decrease in CEC density on the postoperative first and twelfth weeks was not statistically significant in either group (p > 0.05).

CONCLUSION

Although it was found that there was no statistically difference in terms of preventing CEC loss between 1.0% sodium-Hyaluronate and the irrigation method during phacoemulsification, it was observed clinically that 1.0% sodium-hyaluronate can make the procedure easy, safer, very helpful, especially for understanding phacoemulsification.

Для цитирования: Kugu Suleyman, Erdogan Gurkan, Sahin Sevim M, Ozerturk Yusuf. A clinical comparison of safety and efficacy in phacoemulsification with versus without ophthalmic viscoelastic device.. Seminars in ophthalmology. 2013. DOI: 10.3109/08820538.2013.833261.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.