MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ophtha.2013.08.043

Медицинская библиотека · Ophthalmology · 2013

Sutureless 27-gauge needle-guided intrascleral intraocular lens implantation with lamellar scleral dissection.

Yamane Shin, Inoue Maiko, Arakawa Akira, Kadonosono Kazuaki

СтатьяПеревод в очереди

Аннотация

PURPOSE: To report a new technique for performing sutureless intrascleral fixation of a posterior chamber intraocular lens (IOL).

DESIGN

Prospective, noncomparative, interventional case series on the results of sutureless intrascleral fixation of a posterior chamber IOL.

PARTICIPANTS

Thirty-five eyes of 34 consecutive patients with aphakia, dislocated IOL, or subluxated crystalline lens who underwent posterior chamber sutureless implantation of an IOL were studied.

METHODS

The haptics of the IOL were externalized with a 27-gauge needle passed through the ciliary sulcus using the double needle technique. The haptics were fixed in a scleral tunnel made by lamellar scleral dissection. The postoperative tilt of the IOL was measured by swept source optical coherence tomography.

MAIN OUTCOME MEASURES: The best-corrected visual acuity (BCVA), corneal endothelial cell density, IOL tilt, and complications were determined.

RESULTS

The IOLs were fixed with exact centration and axial stability. No wound leakage was seen even without any sutures. The mean BCVA was 0.48 logarithm of the minimum angle of resolution (logMAR) units preoperatively and 0.17 logMAR units at 3 months postoperatively (P = 0.003). The mean corneal endothelial cell loss was 6.0±7.3% (P = 0.63) at 3 months. The mean IOL tilt was 2.3±1.9°. The postoperative complications included iris capture by the IOL in 3 eyes (8.6%), ocular hypertension in 2 (5.7%), and cystoid macular edema in 1 (2.9%). There was no postoperative retinal detachment, endophthalmitis, IOL dislocation, or vitreous hemorrhage.

CONCLUSIONS

The 27-gauge needle-guided intrascleral posterior chamber IOL implantation technique provides good IOL fixation with reliable wound closure without the use of any sutures. We recommend this technique for secondary IOL implantation.

Для цитирования: Yamane Shin, Inoue Maiko, Arakawa Akira, Kadonosono Kazuaki. Sutureless 27-gauge needle-guided intrascleral intraocular lens implantation with lamellar scleral dissection.. Ophthalmology. 2013. DOI: 10.1016/j.ophtha.2013.08.043.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.